Yokogawa 2560A Wide Output Precision DC Calibrator

Yokogawa 2560A Wide Output Precision DC Calibrator

  • DC voltage output −1224.00 V to +1224.00 V across 5 ranges.
  • DC current output −12.2400 A to +36.720 A across 7 ranges.
  • Accuracy ±50 ppm voltage, ±70 ppm current.
  • Stability ±10 ppm/h voltage, ±20 ppm/h current.
  • 10 thermocouple types plus Pt100 RTD simulation.
Send Enquiry

The Gold Standard in DC Calibration

The Model 2560A is a simple, precise and cost-effective solution for calibrating DC measuring instruments such as analog meters, thermometers, temperature transmitters, data loggers and multimeters. Its wide output ranges – 100 mV to 1000 V and 100 µA to 30 A – replace the need for multiple calibrators in one standalone package.

Key Features

  • Wide output range of voltage and current generation – 100 mV to 1000 V and 100 µA to 30 A
  • Dials and switches for each digit and function
  • High accuracy, stability and resolution
  • Effective functions for analog meter calibration – ramp, step and deviation controls for verifying hysteresis
  • Wider output ranges replace the need for multiple calibrators in a single standalone package
  • Suited to verifying data loggers, temperature controllers, thermometers, multimeters and analog panel meters
  • Seven-segment LED displays for clear visibility
  • Built-in interface for integration into an automated test system
  • Two 2560A units can be connected to double the current output to 73.44 A
  • 5½-digit display, or 6½ digits in high-resolution mode

Specifications

Voltage ranges 100 mV / 1 V / 10 V / 100 V / 1000 V (±122.400 mV to ±1224.00 V)
Voltage accuracy (1 year) ±(55 ppm of setting + 15 µV) on 1 V; basic accuracy ±50 ppm
Current ranges 100 µA / 1 mA / 10 mA / 100 mA / 1 A / 10 A / 30 A
Current accuracy (1 year) ±(70 ppm of setting + 30 nA) on 1 mA; basic accuracy ±70 ppm
Max current output +36.720 A single unit; 73.44 A with two units connected
Stability Voltage ±10 ppm/h; current ±20 ppm/h
Maximum output ±122.4% of range
Resolution 5½ digits (±120,000 count); 6½ digits (±1,200,000 count) in high-resolution mode
Thermocouples 10 types plus Pt100 RTD simulation

Leave a Reply

Your email address will not be published. Required fields are marked *

Enjoy:

Send Enquiry For:

Yokogawa 2560A Wide Output Precision DC Calibrator

The details you submit will be used to handle your request, as described in our Privacy Policy.

Israel's Leading Businesses Choose DCT

Israel's Leading Businesses Choose DCT

DCT’s Skilled Management Team has more than twenty-five years of experience and expertise in the local business environment, coupled with a highly motivated group of employees, positions us as the preferred supplier among the major customers in the industry.

DCT Competitive Edge is the prompt response to our customer needs, the online and on-site direct technical support, professional consulting for the best cost/performance solution, on-time delivery, long-term maintenance, and support.

We can get back to you!

The details you submit will be used to handle your request, as described in our Privacy Policy.

Need a Rugged Device?

Fill in the form!

A variety of tablets are available for all use cases.
- only solutions - No obligations -

The details you submit will be used to handle your request, as described in our Privacy Policy.

Our experts can help you find just about anything.

What Were You Looking For? Let us help.

The details you submit will be used to handle your request, as described in our Privacy Policy.