GX6188 Series Specifications
GX6188 Switching Specifications | |
---|---|
Configuration | (4) 26 x 8 matrices and (1) 8 x 8 matrix |
Inputs | 8 via external resource or global bus connections |
Internal Global Bus Configuration | 8-wire, accessible via 104×8 & 8×8 matrices and external connector |
Global Bus Resources | 2.2 KΩ grounded bleed resistor BIT voltage source (100KΩ pullup to 3.3V) |
UUT Inputs / Outputs | 104 |
Relay Specifications | Max AC pk or DC voltage 170 V Max DC or AC pk carry current: 1A Max DC or AC pk switching current: 0.5A Max contact rating: 10 W |
Signal Bandwidth | >10 MHz, Input to Output (resource input to switch card output) |
General Purpose I/O | |
Inputs / Outputs | 14, static read / write digital I/O signals |
Logic Levels | LVTTL compatible |
Functions | Cable ID, open relays via external input, generate PXI bus interrupt via external input |
I/O Connections | |
Output / UUT | (2) 62 pin D-sub F connectors |
Input / Resource | 15 pin D-sub F connector |
Global Bus | 9 pin D-sub F connector |
Environmental, Phsyical and Compliance | |
Operating | GX6188: 0°C to +50°C GX6188-M: 0°C to +85°C |
Storage | GX6188: -20°C to +85°C GX6188-M: -51°C to +85°C |
Relative Humidity (operating) | GX6188: 5% to 85%, temperature range 0°C to 60°C GX6188-M: 5% to 95%, temperature range 0°C to 60°C GX6188, GX6188-M: 5% to 60% for operating temperatures above 60°C |
Altitude (operating) | 4600 meters (max) |
Form Factor | 6U, single slot |
Weight | 2.2 lbs |
CE Compliance | EN61010-1 (pending) EN61326 (pending) |
Note: Specifications are subject to change without notice.