DC Bias Current Source 6223 (20A)

DC Bias Current Source 6223 (20A)

  • High Output Capability Provides a DC bias current of up to 20A per unit, with a maximum total output of 120A using 6 units.
  • Frequency Range Supports a frequency range of 100Hz to 10MHz (depending on the LCR meter/impedance analyzer used).
  • Precise Current Control Offers accurate output current with multiple accuracy levels depending on the range (up to 3% for 5.001A-20.000A).
  • Versatile System Integration Compatible with 6632 Impedance Analyzer or 6355/6356 LCR Meter for various measurement and analysis applications.
  • Robust Design Compact and durable with a power consumption of 320W max, designed for use in temperature ranges from 10℃ to 40℃.
Send Enquiry

Features

  • Up to 10MHz
  • Each individual unit can output DC Bias Current 20A (Max.120A)
  • Control by the LCR Meter or Impedance Analyzer

Application

How DC Bias current helps inductor testing?

Ferromagnetic materials (like iron) are composed of microscopic regions called magnetic domains. The stronger the external magnetic field H, the more the domains align, yielding a higher magnetic flux density B. Eventually, The magnetization remains nearly constant, and is said to have saturated. The domain structure at saturation depends on the temperature.

What is magnetic saturation?

In electronic circuits, transformers and inductors with ferromagnetic cores operate nonlinearly when the current through them is large enough to drive their core materials into saturation. This means that their inductance and other properties vary with changes in drive current. In linear circuits this is usually considered an unwanted departure from ideal behavior.

 

Magnetic saturation current is called Isat, and the temperature rise current is called I rms. When the transformer and the inductor pass a large current in the actual circuit operation, the magnetic field of the magnetic core will produce magnetic saturation, which will cause the inductance characteristic to decline. Therefore, the R&D engineer will set the current value of the inductance reduction allowable range.

Option 6632+6243 DC Bias Curretnt Test System

Supports magnetic saturation current analysis measurement function.

Isat (Magnetic saturation current curve)

Irms (Rated current curve)

Using a DC Bias current source to apply a 200A bias current to the inductor, the inductance decreased from 2.06983uH to 1.02845uH.

Equivalent Circuit Analysis (Option)

It has seven different models, combine with different types of parameters ( R, L, C) help customers model the impedance versus frequency characteristics and self-resonant frequency (SRF).

Magnetic Material Test Fixture (FX-0000C8)

Using the magnetic material test fixture for measuring of permeability of various toroidal cores or ferrite cores and electromagnetic shielding coating materials, 6632 built-in formula to directly calculate the permeability coefficient value μr.

List Mode

50 groups of list mode setting (Each group contains up to 15 steps).

The DC Bias Current Source 6223 (20A) is a high-performance device designed to provide precise DC bias current for testing and analysis of inductors. With a single unit capable of delivering up to 20A of DC bias current and a maximum total output of 120A when using six units, it is ideal for performing magnetic saturation current (Isat) and temperature rise current (Irms) analysis. The 6223 works seamlessly with the 6632 Impedance Analyzer or 6355/6356 LCR Meter, offering a broad frequency range from 100Hz to 10MHz, depending on the analyzer or meter chosen. The system provides highly accurate current control with varying levels of precision, ranging from 1% accuracy for lower currents to 3% for higher currents. Compact and efficient, the 6223 operates within a power consumption of 320W and is designed to perform in environments with temperatures between 10℃ and 40℃. Its robust interface options (RS-232, Handler) and user-friendly features make it an essential tool for precise inductor testing and analysis.

Specifications

DC Bias Current Source

Model 6223
DC Bias Current Max. 120A
units of the DC Bias 6
Power consumption 320W Max.
Output Current (unit) 20A
Option LCR Meter/Impedance Analyzer
6632/6356/6355
Option LCR Meter/Impedance Analyzer Frequency Response
6632 100Hz-10MHz
6356 100Hz-500kHz
6355 100Hz-200kHz
DC Bias Current Source 6223
 Accuracy (6632) 0.000A-1.000A 1%+5mA
1.001A-5.000A 2%
5.001A-20.000A 3%
DCR Test
Constant power output
Current switch

System

   Power Supply Voltage:88-264Vac
Frequency:47-63Hz
  Environment Temperature:10℃-40℃
Humidity:20-90%RH
Dimension 337x145x525 mm (W*H*D)/6223
  Weight 15 Kg (6223)
Display
Interface RS-232、Handler

Accessories

Standard Accessories

  Power Cord
  DIP Test Fixture-DC Bias Current  (F6210)

Optional Accessories

  PC Link Software
  SMD Test Fixture-DC Bias Current  (F6220)
  BNC+BNC cable

Enjoy:

Send Enquiry For:

DC Bias Current Source 6223 (20A)

Israel's Leading Businesses Choose DCT

Israel's Leading Businesses Choose DCT

DCT’s Skilled Management Team has more than twenty-five years of experience and expertise in the local business environment, coupled with a highly motivated group of employees, positions us as the preferred supplier among the major customers in the industry.

DCT Competitive Edge is the prompt response to our customer needs, the online and on-site direct technical support, professional consulting for the best cost/performance solution, on-time delivery, long-term maintenance, and support.

We can get back to you!

Need a Rugged Device?

Fill in the form!

A variety of tablets are available for all use cases.
- only solutions - No obligations -

Our experts can help you find just about anything.

What Were You Looking For? Let us help.