Oscilloscope probe SI-9002

Oscilloscope probe SI-9002

  • High Voltage Differential Input: Measures high-voltage differential signals up to 1400 V (DC+Peak AC).

  • Bandwidth: DC to 25 MHz for accurate measurements across a wide frequency range.

  • Attenuation Options: Selectable 1/20 or 1/200 attenuation ratios for versatile voltage scaling.

  • High Accuracy: ±2% accuracy with a rise time of 14 ns for precise signal analysis.

  • Compact and Lightweight: Small form factor (170 mm length, 21 mm height) with easy portability and setup.

Send Enquiry

Features

  • High Voltage Differential Input: Measures voltages up to ±1400 V (DC+Peak AC), suitable for power semiconductor circuits.

  • Bandwidth: DC to 25 MHz (-3dB), providing accurate measurements for a wide range of applications.

  • Attenuation Ratios: Selectable 1/20 or 1/200 for versatile voltage scaling.

  • High Accuracy: ±2% accuracy with a fast rise time of 14 ns for precise and reliable measurements.

  • Compact and Lightweight Design: Portable design with a length of 170 mm and weight of just 400 g for easy handling and storage.

  • Common Mode Range: ±1400 V (DC+Peak AC), enabling accurate differential measurements even in high-voltage environments.

  • Low Noise: Typical noise level of 0.7 mVrms, ensuring minimal signal interference.

  • Impedance: 50 Ohms (for use with a 1 MΩ oscilloscope input system), ensuring compatibility with standard oscilloscopes.

  • Power Supply: Powered by 4 x AA cells or a 9 VDC mains adapter (optional).

  • Safety Features: CAT III rated, with built-in protection against incorrect polarity.

The Differential probe SI-9002 extends the measurement power of oscilloscopes to power semiconductor circuits. This Differential Probe provides any general oscilloscope with a high voltage differential input.

The Differential probe SI-9002 is small and light, so it can be used in a very convenient way; just plug it into the input of, for example, the Handyscope HS5. The wide bandwidth and the high accuracy of this Differential Probe cater for a wide range of applications.

Using a built-in differential amplifier, the Differential probe SI-9002 scales and converts the high voltage differential input to a low voltage single ended BNC output. The differential input is useful in measurements of power semiconductor circuits, as no reference to ground is required. Both the positive and negative sides of the balanced input possess high voltage differential input up to 700 V, and its sensitivity can extend down to 100 mV. With high bandwidth and high response speed, the Differential probe SI-9002 is adequate for accurate dV/dt measurement in the fastest switching circuits of thyristors, bipolar transistors, or power MOSFETS.

Specification

Specification Value
Bandwidth DC to 25 MHz (-3dB)
Attenuation Ratio 1/20 or 1/200
Accuracy ±2%
Rise Time 14 ns
Input Impedance 4 MΩ, 5.5 pF each side ground
Input Voltage Differential Range 1/20: ±140 V (DC+Peak AC) or 140 VrmsDifferential Range 1/200: ±1400 V (DC+Peak AC) or 1000 Vrms
Common Mode Range ±1400 V (DC+Peak AC) or 1000 Vrms
Absolute Max. Voltage ±1400 V (DC+Peak AC) or 1000 Vrms CAT III
Output Swing ±7 V (into 2kΩ load)
Offset (typical) < ±5 mV
Noise (typical) 0.7 mVrms
Impedance (typical) 50 Ω (for 1 MΩ oscilloscope input system)
CMRR (typical) -80 dB @ 50 Hz, -60 dB @ 20 kHz
Operating Temperature -10 to 40 °C (14 to 104 °F)
Storage Temperature -30 to 70 °C (-22 to 158 °F)
Operating Humidity 25 to 85% RH
Storage Humidity 25 to 85% RH
Power Requirements 4 x AA cells or regulated 9 VDC / 40 mA mains adapter
Length of BNC Cable 95 cm (37.4 inches)
Length of Input Leads 45 cm (17.7 inches)
Weight 400 g (14.1 ounces)
Dimensions (H x L x W) 21 mm x 170 mm x 63 mm (0.8″ x 6.7″ x 2.5″)

Voltage limit is the lesser of the DC+Peak AC and RMS values.
The supplied voltage must be less than 12V and greater than 4.4V, otherwise the differential probe could be damaged or can’t be operated properly.
Polarity is “+” inside and “-” outside. For wrong polarity, built-in circuit protects the differential probe, no danger or damage will occur.
When the voltage of the cells become too low, the power indicator on the panel will flicker.

Information

When using the Differential probe SI-9002 in combination with:

Handyscope HS4 DIFF
Handyscope HS6 DIFF without option SafeGround
WiFiScope WS4 DIFF
WiFiScope WS6 DIFF without option SafeGround
an extra grounding connection between the instrument and the Differential probe SI-9002 is required. When ordering a Differential probe SI-9002 to be used with one of these instruments, please mention that you also want the extra ground lead for the Differential probe SI-9002 and specify for which instrument.

Information:
When using the Differential probe SI-9002 in combination with

Handyscope HS6 DIFF with option SafeGround
WiFiScope WS6 DIFF with option SafeGround
the used input channel of the scope must be set to single ended.

Accessories

The Differential probe SI-9002 is delivered with:

Amount Item
1 Differential probe SI-9002
1 Protective rubber shell
1 Manual

Enjoy:

Send Enquiry For:

Oscilloscope probe SI-9002

Israel's Leading Businesses Choose DCT

Israel's Leading Businesses Choose DCT

DCT’s Skilled Management Team has more than twenty-five years of experience and expertise in the local business environment, coupled with a highly motivated group of employees, positions us as the preferred supplier among the major customers in the industry.

DCT Competitive Edge is the prompt response to our customer needs, the online and on-site direct technical support, professional consulting for the best cost/performance solution, on-time delivery, long-term maintenance, and support.

We can get back to you!

Need a Rugged Device?

Fill in the form!

A variety of tablets are available for all use cases.
- only solutions - No obligations -

Our experts can help you find just about anything.

What Were You Looking For? Let us help.