- 48VDC (44~57VDC) redundant dual power input
- 4 IEEE 802.3af / 802.3at PoE+ ports, delivering 60W per port (total 240W)
- Cable diagnostics to identify open/short distances
- Supports 5 ring instances, with μ-Ring, μ-Chain, or Sub-Ring topology options
- μ-Ring provides redundant cabling with recovery time <10ms for up to 250 devices
- Supports EMS management for monitoring and configuration
Industrial Managed GbE PoE Switch IGS-402SM-4PU
- 4x Gigabit Ethernet Ports Supports IEEE 802.3af/at PoE+ with 60W per port (240W total) for high-power devices.
- 2x SFP Slots Offers 100/1000Base-X fiber optic connectivity for extended transmission distances.
- Redundant 48VDC Power Dual power input (44~57VDC) ensures reliable operation in critical environments.
- Advanced Ring Topology Supports up to 5 μ-Ring instances for flexible, redundant cabling with recovery time under 10ms.
- Durable & Secure Fanless design, 4KV surge protection, wide operating temperature range, and cable diagnostics for robust performance in harsh industrial environments.
The IGS-402SM-4PU is a rugged, industrial-grade managed Ethernet switch designed for demanding environments. It features four Gigabit Ethernet RJ45 ports, each capable of delivering up to 60W of Power over Ethernet (PoE+) for high-power devices, with a total PoE budget of 240W. Additionally, it includes two 100/1000Base-X SFP slots for flexible fiber optic connectivity, ideal for long-distance transmission. This fanless switch is built for durability, with a high Mean Time Between Failures (MTBF), 4KV surge protection, and a wide operating temperature range, making it suitable for industrial automation, data centers, intelligent transportation systems, and military applications. The switch offers redundant 48VDC power input for continuous operation, and its advanced features include cable diagnostics for identifying opens and shorts, as well as support for flexible network topologies with up to five ring instances (μ-Ring, μ-Chain, or Sub-Ring), ensuring fast recovery times of under 10ms in networks with up to 250 devices. The IGS-402SM-4PU also supports EMS management for easy monitoring and configuration.
Specifications
Standard | IEEE 802.3 | 10Base-T 10Mbit/s Ethernet |
IEEE 802.3u | 100Base-TX, 100Base-FX, Fast Ethernet | |
IEEE 802.3ab | 1000Base-T Gbit/s Ethernet over twisted pair | |
IEEE 802.3z | 1000Base-X Gbit/s Ethernet over Fiber-Optic | |
IEEE 802.3af | PoE (Power over Ethernet) | |
IEEE 802.3at | PoE+Â (Power over Ethernet enhancements) | |
IEEE 802.1d | STP (Spanning Tree Protocol) | |
IEEE 802.1w | RSTP (Rapid Spanning Tree Protocol ) | |
IEEE 802.1s | MSTP (Multiple Spanning Tree Protocol) | |
ITU-T G.8032 / Y.1344 | ERPS (Ethernet Ring Protection Switching) | |
IEEE 802.1Q | Virtual LANs (VLAN) | |
IEEE 802.1X | Port based and MAC based Network Access Control, Authentication | |
IEEE 802.3ac | Max frame size extended to 1522Bytes | |
IEEE 802.3ad | Link aggregation for parallel links with LACP (Link Aggregation Control Protocol) | |
IEEE 802.3x | Flow control for Full Duplex | |
IEEE 802.1ad | Stacked VLANs, Q-in-Q | |
IEEE 802.1p | LAN Layer 2 QoS/CoS Protocol for Traffic Prioritization | |
IEEE 802.1ab | Link Layer Discovery Protocol (LLDP) | |
IEEE 802.3az | EEE (Energy Efficient Ethernet) |
Switch Architecture | Back-Plane (Switching Fabric): 12Gbps (Full Wire-Speed) | ||||
Data Processing | Store and Forward | ||||
Flow Control | IEEE 802.3x for full duplex mode Back pressure for half duplex mode | ||||
Network Connector | 4x 10/100/1000Base-T RJ-45 + 2x 100/1000Base-X SFP | ||||
RJ-45 UTP port supports Auto negotiation speed, Auto MDI/MDI-X function | |||||
SFP port supports 100/1000 dual speed with DDMI | |||||
Console | RS-232 (RJ-45) | ||||
PoE Standard & RJ-45 Pin Assignment | 4x IEEE 802.3at/ 802.3af PoE+
4 pairs PoE, 60W/port End-Span, Alternative A and B mode. Positive (V+) : RJ-45 pin 1, 2, 4, 5 Negative (V-) : RJ-45 pin 3, 6, 7, 8 |
||||
Network Cable | UTP/STP above Cat. 5e cable | ||||
EIA/TIA-568 100-ohm (100m) | |||||
Protocols | CSMA/CD | ||||
Reverse Polarity Protection | Supported for power input | ||||
Overload Current Protection | Supported | ||||
CPU Watch Dog | Supported | ||||
Power Supply | Redundant Dual DC 48V (44~57VDC) input power, (Removable terminal block )
(50~57V input is recommended for IEEE802.3at PoE+Â in 30W/ 60W applications) |
||||
Power Consumption | Input Voltage | Total Power Consumption | Device Power Consumption | PoE Budget | |
50VDC | 249.6W | 9.6W | 240W | ||
PoE Power Budget | Maximum PoE Output power budget 60W/port Total 240W | ||||
LED | System: Power 1 (Green), Power 2 (Green), Fault (Amber), CPU Act (Green), Ring Master (Yellow) | ||||
UTP: 10/100 Link/Active (Green), 1000 Link/Active (Amber) | |||||
SFP Slot: Link/Active (Green) | |||||
PoE: ON (Green) | |||||
Jumbo Frame | 9.6KB | ||||
IEEE802.3ac | Max frame size extended to 1522Bytes (allow Q-tag in packet) | ||||
MAC Address Table | 8K | ||||
Memory Buffer | 512K Bytes for packet buffer | ||||
Device Memory | 16M Bytes Flash ROM, 128M Bytes RAM | ||||
Warning Message | System Syslog, SMTP/ e-mail event message, alarm relay | ||||
Alarm Relay Contact | Relay outputs with current carrying capacity of 1A @24VDC | ||||
Removable Terminal Block | Provide 2 redundant power, alarm relay contact, 6 Pin | ||||
Operating Temperature | -10 ~ 60°C (IGS-402SM-4PU)
-40 ~ 75°C (IGS-402SM-4PUE) |
||||
Operating Humidity | 5% to 95% (Non-condensing) | ||||
Storage Temperature | -40 ~ 85°C | ||||
Housing | Rugged Metal, IP30 Protection, Fanless | ||||
Dimensions | 106 x 62.5 x 135mm (D x W x H) | ||||
Weight | 0.7kg | ||||
Installation Mounting | DIN Rail mounting or wall mounting (Optional) | ||||
MTBF | 589,078 Hours (MIL-HDBK-217) | ||||
Warranty | 5 years | ||||
Certification | |||||
EMC | CE (EN55024, EN55032) | ||||
EMI (Electromagnetic
Interference) |
FCC Part 15 Subpart B Class A, CE | ||||
Railway Traffic | EN50121-4 | ||||
Immunity for Heavy Industrial Environment | EN61000-6-2 | ||||
Emission for Heavy Industrial Environment | EN61000-6-4 |
EMS
(Electromagnetic Susceptibility) Protection Level |
EN61000-4-2 (ESD) Level 3, Criteria B |
EN61000-4-3 (RS) Level 3, Criteria A | |
EN61000-4-4 (Burst) Level 3, Criteria A | |
EN61000-4-5 (Surge) Level 3, Criteria B | |
EMS (Electromagnetic
Susceptibility) Protection Level |
EN61000-4-6 (CS) Level 3, Criteria A |
EN61000-4-8 (PFMF, Magnetic Field) Field Strength: 300A/m, Criteria A | |
Safety | UL60950-1, EN60950-1, EN62368-1 |
Surge Protection | 4KV for PoE, UTP and Fiber ports |
Shock | IEC 60068-2-27 |
Freefall | IEC 60068-2-32 |
Vibration | IEC 60068-2-6 |
Software Specifications
Topology | |
VLAN | IEEE 802.1q VLAN, up to 4094 802.1Q VLAN ID |
IEEE 802.1q VLAN, up to 4094 Groups | |
IEEE 802.1ad Q-in-Q | |
MAC-based VLAN, up to 256 entries | |
IP Subnet-based VLAN, up to 128 entries | |
Protocol-based VLAN (Ethernt, SNAP, LLC), up to 128 entries | |
VLAN Translation, up to 256 entries | |
Private VLAN for port isolation | |
GVRP (GARP VLAN Registration Protocol) | |
MVR (Multicast VLAN Registration) | |
Voice VLAN | |
Link Aggregation
(Port Trunk) |
Static (Hash with SA, DA, IP, TCP/UDP port), up to 5 trunk group |
Dynamic (IEEE 802.3ad LACP), up to 5 trunk group | |
Spanning Tree | IEEE 802.1d STP, IEEE 802.1w RSTP, IEEE 802.1s MSTP |
Multiple µ-Ring | Up to 5 instances that each supports μ-Ring, μ-Chain or Sub-Ring type for flexible uses, and maximum up to 5 Rings |
Recovery time <10ms | |
The maximum number of device is allowed 250 nodes in a Ring. | |
Loop Protection | Supported |
ITU-T G.8032 / Y.1344 ERPS
(Ethernet Ring Protection ) |
Recovery time <50ms |
Single Ring, Sub-Ring, Multiple ring topology network | |
QoS Features | |
Class of Service | IEEE 802.1p 8 active priorities queues for per port |
Traffic Classification QoS | IEEE 802.1p based CoS, IP Precedence based CoS, IP DSCP based CoS |
QCL (QoS Control List): Frame Type, Source/Destination MAC, VLAN ID, PCP, DEI, Protocol, Source IP, IP Fragment, DSCP, TCP/UDP port number | |
Bandwidth Control for Ingress | 100~1,000,000 when the “Unit” is “kbps”, and 1~1,000 when the “Unit” is “Mbps” |
Bandwidth Control for Egress | 100~1,000,000 when the “Unit” is “kbps”, and 1~1,000 when the “Unit” is “Mbps” |
Per queue / Port shaper | |
DiffServ (RF 2474) Remarking | |
Storm Control | For Unicast, Broadcast and Multicast |
IP Multicasting Features | |
IGMP / MLD Snooping | IGMP Snooping v1, v2, v3 / MLD Snooping v1, v2 |
Port Filtering Profile | |
Throttling | |
Fast Leave | |
Maximum Multicast Group : up to 1022 entries | |
Query / Static Router Port |
Security Features | |
IEEE 802.1X | Port-Based |
MAC-Based | |
ACL | Number of rules : up to 256 entries |
for L2 / L3 / L4
L2 : Mac address SA/DA/VLAN L3: IP address SA/DA, Subnet L4: TCP/UDP |
|
RADIUS | Authentication & Accounting |
TACACS+ | Authentication |
HTTPS, HTTP | Supported |
SSL / SSH v2 | Supported |
User Name Password
Authentication |
Local Authentication |
Remote Authentication (via RADIUS / TACACS+) | |
Management Interface Access Filtering | Web, Telnet / SSH, CLI RS-232 console |
Management Features | |
CLI | Cisco® like CLI |
Web UI | Supported |
Telnet | Server |
SNMP | V1, V2c, V3 |
Modbus/TCP | Supports for management and monitoring |
SW & Configuration Upgrade | TFTP, HTTP |
Redundant firmware in case of upgrade failure | |
FTP client | Supports for upload/download configuration |
RMON | RMON I (1, 2, 3, 9 group), RMON II |
MIB | RFC1213 MIB II, Private MIB |
UPnP | Supported |
BOOTP | Supported |
DHCP | Server, Client, Relay, Relay option 82, Snooping |
RARP | Supported |
IP Source Guard | Supported |
Port Mirroring | Supported |
Event Syslog | Syslog server (RFC3164) |
Warning Message | System syslog, e-mail, alarm relay |
DNS | Client, Proxy |
IEEE1588 PTP V2 | Supports 5 operating mode in each port :
Ordinary-Boundary, Peer to Peer Transparent Clock, End to End Transparent Clock, Master and Slave |
NTP, SNTP | Client |
LLDP (IEEE 802.1ab) | Link Layer Discovery Protocol |
LLDP-MED | |
IPv6 Features | |
IPv6 Management | Telnet Server/ICMP v6 |
SNMP over IPv6 | Supported |
HTTP over IPv6 | Supported |
SSH over IPv6 | Supported |
IPv6 Telnet | Supported |
IPv6 NTP, SNTP | Client |
IPv6 TFTP | Supported |
IPv6 QoS | Supported |
IPv6 ACL | Number of rules: up to 256 entries |
for L2 / L3 / L4
L2 : Mac address SA/DA/VLAN L3: IP address SIP, Subnet (32bit) L4: TCP/UDP |
Â
Others Features | |
Green Ethernet | Supports IEEE 802.3az EEE (Energy Efficient Ethernet) Management to optimize the power consumption |
Determine the cable length and lowering the power for ports with short cables | |
Lower the power for a port when there is no link | |
LED Power Management :Adjustment LEDs intensity | |
Cable Diagnostic | Measuring UTP cable normal or broken point distance |
Advanced PoE | |
Management | PoE PD failure auto checking, and auto reset when PD fail PoE port on/off weekly scheduling
PoE Configuration PoE Enable/Disable Power limit by classification Power feeding priority Total PoE power budget limitation: maximum 240W |
Optional Accessories
Wall Mount Kit
IND-WMK05Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Wall Mount kit for Industrial product (2pcs in 1 set, 42 x 30mm)
Industrial SFP Transceiver
The ISFP series of industrial grade SFP modules have been fully tested with all CTC Union industrial grade Ethernet switches for guaranteed compatibility and performance. Best performance can be guaranteed, even in mission-critical applications. (Please see CTC Union’s Industrial SFP datasheets for more items and detailed information.)
ISFP-M7000-85-D(E) | Industrial SFP GbE 1000Base-SX, M/M, 500 meter,wave length 850nm, 7.5dB, LC, DDMI, -10~70°C (-40~85°C) |
ISFP-S7020-31-D(E) | Industrial SFP 1000Base-LX, S/M, 20km, wave length 1310nm, 15dB, LC, DDMI, -10~70°C (-40~85°C) |
ISFP-T7T00-00-(E) | Industrial SFP 10/100/1000Base-T UTP 100meter, -10~70°C (-40~85°C) |
ISFP-M5002-31-D(E) | Industrial SFP 155M 100Base-FX, MM, 2km, wave length 1310nm, 12dB, LC, DDMI, -10~70°C (-40~85°C) |
ISFP-S5030-31-D(E) | Industrial SFP 155M 100Base-FX, SM, 30km, 1310nm, 19dB, LC, DDMI, -10~70°C (-40~85°C) |
Industrial Power Supply
NDR-240-48  Industrial Power, Input 90 ~ 264VAC/127 ~ 370VDC, Output 48VDC, 240W, -20 ~ 70°C
NDR-480-48  Industrial Power, Input 90 ~ 264VAC/127 ~ 370VDC, Output 48VDC, 480W, -20 ~ 70°C
Â
Â
Enjoy:
- Nearly 30 Years of Experience
- Reliable Suppliers
- Quality Products
- Free Technical Consultation
- Tailoring Custom Solution
- Expert Technical Support
- No Hidden-Fees
Send Enquiry For:
Industrial Managed GbE PoE Switch IGS-402SM-4PU
Israel's Leading Businesses Choose DCT
Israel's Leading Businesses Choose DCT
DCT’s Skilled Management Team has more than twenty-five years of experience and expertise in the local business environment, coupled with a highly motivated group of employees, positions us as the preferred supplier among the major customers in the industry.
DCT Competitive Edge is the prompt response to our customer needs, the online and on-site direct technical support, professional consulting for the best cost/performance solution, on-time delivery, long-term maintenance, and support.
Still Conflicted? Let's Talk.
We can get back to you!