GX7800 Series Specifications
Chassis | |
---|---|
Input AC Power | 90 – 264 VAC, 10 A (max), 47-63 Hz |
Total Available DC System Power | 450 W |
+5 V +3.3 V +12 V -12 V Note: Total power cannot exceed 450 W |
30 A (max) 30 A (max) 10 A (max) 5 A (max) |
Weight | 13 lbs |
Dimensions | 4U (7″) H x 8.9″ W x 18″ D |
Cooling | Two 79 CFM fans for system cooling. Dedicated 50 CFM fan for power supply cooling. |
PXI Triggers | Slots: 2 – 8 Number: 8 |
PXI Star Trigger | Slots: 2 – 8 Dedicated, low skew Star trigger connecting slots 3 – 8 to slot 2, the PXI system timing slot |
PXI Clock and Synchronization Resources | Integrated 10 MHz clock with an autodetect function. Presence of an external 10 MHz PXI clock will overide the internal 10 MHz clock 10 MHz clock accuracy: ±100 ppm |
External 10 MHz Clock Input | An external 10 MHz clock source (TTL level) can be provided via a rear panel BNC or via a PXI System Timing Controller |
10 MHz Clock Output | 10 MHz output is available via a rear panel BNC connector, TTL compatible level. |
Slots | 8 Slots (7 instruments max) 1 PXI controller slot 6 PXI slots 1 PXI System Timing slot |
Environmental | |
---|---|
Acoustic Noise (at operator level, 12 inches from front of unit) |
Low fan setting (@ 23°C ambient): <40  dBA High fan setting: 64.6 dBA |
Operating Temperature | 0 °C to +50 °C |
Storage Temperature | -20 °C to +60 °C |
Emissions Compliance | EN55011:1991 Group 1 |
CE Compliance | EN 61010-1 EN61326 |
Note: Specifications are subject to change without notice.