Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the dynamic-content-for-elementor domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/dcttempu/public_html/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the iksm domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/dcttempu/public_html/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the rocket domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/dcttempu/public_html/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the wordpress-seo domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/dcttempu/public_html/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the breadcrumb-navxt domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/dcttempu/public_html/wp-includes/functions.php on line 6114
GX7100e Series | DCT | Test and Measurement

DCT | Test and Measurement

Welcome to our new site! Feel free to report any issues, contact us at Marketing@dct.co.il

GX7100e Series

GX7100e Series

3U / 6U PXIe Chassis

  • 14-slot 3U / 6U PXI Express combo chassis with 4×4 Gen2 backplane
  • Accommodates a single slot 3U PXIe controller, one 3U PXIe, three 3U hybrid, two PXI-1 and seven 6U hybrid slot compatible instruments
  • Built-in hard disk drive for embedded controller configurations
  • Integral Smart functions provide internal temperature monitoring, power supply monitoring, fan control and PXI trigger mapping
  • Optional cable tray, recessed card cage, and hinged front panel configurations for mass interconnect devices
Send Enquiry

GX7100e Series Specifications

Chassis Specifications
Input AC Power 90 – 264 VAC, 47 – 63 Hz, 11 A max with PFC
Total Available DC Power 650 W
+5 V
+3.3 V
+12 V
-12 V
Note: Total PXI power cannot exceed 650 W
60 A (max)
40 A (max)
35 A (max)
5 A (max)
Weight
GX7100e
GX7110e
GX7102e
GX7112e
26 lbs
23 lbs
28 lbs
25 lbs
Dimensions
GX7100e
GX7110e
GX7102e
GX7112e
4U (7″) H x 17.6″ W x 16″ D
4U (7″) H x 17.6″ W x 16″ D
6U (10.5″) H x 17.6″ W x 23″ D
6U (10.5″) H x 17.6″ W x 23″ D
Cooling
  • Eight 20 CFM fans for instruments
  • Additional fan for the system power supply
PXI Clock Integrated 10 MHz PXI clock with auto-detect function. Presence of an external 10 MHz PXI clock will disable the internal clock. PXI clock is distributed to all peripheral slots.
Optional external clock can be supplied via slot 2 or via the rear panel 10 MHz input.
Temperature Monitoring 7 temperature sensors, centrally located across segment A, 1 reading/sec/sensor
4 second moving average value
User selectable alarm criteria:

  • Maximum slot temperature
  • Average slot temperature

Accuracy: ±1 °C
Default warning and shutdown limits: +50 °C and +70 °C
Warning and shutdown limits programmable via software driver
Status: Query via software driver and audible alarm for a warning limit condition

Power Supply Monitoring Monitored voltages: 3.3, 5, +12, -12, VIO value
Accuracy: ±1% of reading
PXI Triggers Slots: 2 – 14
Number: 8 per segment
Software controlled segment mapping supports:

  • Isolate a trigger line within a segment
  • Map a trigger line from segment A to B
  • Map a trigger line from segment B to A
Slot Configuration (7) 6U PXI hybrid peripheral slots
(1) 3U PXIe controller slot
(1) 3U PXIe peripheral slot
(2) 3U PXI-1 peripheral slots
(3) 3U PXIe peripheral hybrid slots
GX7100e / GX7102e Peripherals 500 GB (min) Hard Drive, 7200 rpm
Environmental Specifications
Acoustic Noise
(at operator level, 12 inches from front of unit)
Auto or High fan setting (@ 23°C ambient): < 40 dBA
Operating 0 °C to +50 °C
Storage -20 °C to +60 °C

Note: Specifications are subject to change without notice.

The GX7100e Series are 14-slot combination PXIe chassis that accommodate a 3U PXIe embedded controller or a MXI express controller as well as 3U & 6U PXI / PXIe insruments in 4U of rack space. The GX7100e’s unique format includes seven 6U slots and seven 3U slots arranged horizontally to reduce the overall size of the chassis, providing the versatility and high-density necessary to address many PXI / PXIe applications and requirements. The backplane architecture supports Gen 2, 4×4 PCI Express bus signaling and the use of both x1 or x4 system controllers. By offering a combination of PXI-1, Hybrid, and Express slots, the GX7100e offers users the ultimate in flexibility for general purpose as well as high bandwidth test needs.

Features

The GX7100e Series offers a full range of features and options including an innovative forced-air cooling system comprised of eight (8) 20 CFM fans controlled by built-in temperature sensors. The fans provide airflow according to PXI revision 2.1 specifications. This cooling configuration provides optimum cooling for the chassis regardless of the type or number of instruments used. Additional cooling is provided for the system power supply.

The GX7100e Smart Chassis supports the monitoring of internal chassis temperatures and system power supply voltages as well providing the ability to program or map each PXI trigger line from one PCI segment to another. In addition, the user can program the temperature monitoring function for specific warning and shutdown limits. All user specific setups can be stored in non-volatile memory as a user configuration and can be used as the default setup for normal chassis operation.

For applications requiring mass interconnect and cable routing to/ from the rear of the chassis, the GX7100e Series offers the ideal system solution. These chassis include an integrated 2U cable tray, a hinged front-panel that accommodates all popular mass interconnect devices, optional openings at the top and bottom of chassis for cable routing, and recessed PXI instruments (recessed by 2.5″ or 5″). The combination of front panel and the recessed instruments provides up to 8″ of space for interface wiring.

The GX7100e Series provides 650 W of system power and complies with the PXI Hardware Specification PXI-5, Rev. 2.0.

Configuration

Slot 1 (3U) is dedicated to the system controller (embedded or remote, using a PXIe bus expander). Slot 2 can be used by a PXIe or cPCIe peripheral.Slots 3 and 4 support 3U PXI-1 peripherals and slots 5-7 support 3U PXI hybrid slot compatible peripherals. Slots 8 -14 support 6U hybrid slot compatible peripherals.

Programming and Software

The chassis is supplied with the GxChassis software which provides software libraries and a driver, programming examples, virtual panel application and documentation. The virtual panel provides a way to control, configure and display the smart chassis’ features, including temperature monitoring, trigger line mapping, and power supply voltage monitoring. A 32/64-bit Windows DLL driver is provided with various interface files for accessing the DLL functions from programming tools and languages such as ATEasy, LabVIEW, C/C++, Microsoft Visual Basic®, Delphi, and more. A User’s Guide provides documentation that includes instructions for installing, using and programming the chassis. Support for Linux for the chassis is provided using a separate software package – GtLinux.

Applications

  • Automatic Test Equipment (ATE)
  • Data Acquisition
  • Production Test
  • Portable Systems

Enjoy:

Send Enquiry For:

GX7100e Series

Israel's Leading Businesses Choose DCT

Israel's Leading Businesses Choose DCT

DCT’s Skilled Management Team has more than twenty-five years of experience and expertise in the local business environment, coupled with a highly motivated group of employees, positions us as the preferred supplier among the major customers in the industry.

DCT Competitive Edge is the prompt response to our customer needs, the online and on-site direct technical support, professional consulting for the best cost/performance solution, on-time delivery, long-term maintenance, and support.

We can get back to you!

Need a Rugged Device?

Fill in the form!

A variety of tablets are available for all use cases.
- only solutions - No obligations -

Our experts can help you find just about anything.

What Were You Looking For? Let us help.