DCT | Test and Measurement

Welcome to our new site! Feel free to report any issues, contact us at [email protected]

GX7017 Series

GENASYS Switching / Digital Subsystem with SCOUT 6U Receiver

  • 6U PXI chassis with integrated MAC Panel SCOUT receiver
  • 20 slot 6U PXI chassis supports GENASYS digital subsystem, PXI modules, and switching subsystem modules
  • Supports multiplexed, hybrid pin & HF connections
  • Supports up to 256 digital channels & 2304 hybrid pins
Send Enquiry

GX7017 Series Specifications

Switching Subsystem Specifications
GX6032 Switch Card Configuration: 32 x16
Max Inputs: 32 to 128 (4 switch cards)
GX6256 LF Switch Card Configuration: 16 x16 matrix with 2 to 1 selector, (16) 2:16 multiplexers
Inputs: 16 internal analog bus and 16 digital
Outputs: 256
Maximum of 9 cards (2304 channels) per system
GX6192 HF Switch Card Configuration: 16 x 16 matrix with (16) 1:12 multiplexers
Inputs: 16 external analog inputs or 16 internal analog bus
Outputs: 192
GX6864 RF Switch Card Bandwidth: 500 MHz
Impedance: 75Ω
Configuration: (4) 2 x 16 multiplexers
Inputs: 16 internal analog bus, 8 external
Relay Specifications Max AC pk or DC voltage 170 V
Max DC or AC pk carry current: 1A
Max DC or AC pk switching current: 0.5A
Max. contact rating: 10 W
Signal Bandwidth
Input to Output (input switch card to LF switch card output) > 20 MHz
HF Switch Card (external input to output) > 100 MHz
I/O Connections
GX6032 Switch Card 32 coaxial connections (Positronics BD8W8F85R70T0/AA)
GX6256 Switch Card Receiver: Dual 200 pin connector
Digital I/O: 34 pin, dual row latched header
GX6192 Switch Card Receiver: Dual 200 pin connector
Digital I/O: 34 pin, dual row latched header
External I/O: 16 coaxial connections (Positronics BD8W8F85R70T0/AA)



Dynamic Digital Subsystem
Configuration 6U PXI format, (7) 32 channel DIO cards, (1) 16 channel DIO card,
programmable drive / sense per pin, 50 MHz vector rate (max)
Number of Hyrid Channels 224
Test Modes Dynamic or static
Data Output Formats (per channel) Drive Hi, Drive Lo, Hi-Z
Formatted Data: No return, Return to 1, Return to 0, Return to Hi-Z, Return to complement, Surround by complement; selectable on a per channel basis
Drive Data Timing (per channel) Data assert / de-assert based on Phases 1-4
Timing Sets 256 Timing Set groups with 4 Phases, 4 Windows, and 4K sequence steps)
Phase Programming Range (Assert/Return) 0 ns to 64 us (using the 500 MHz master clock)
Window Programming Range (Open/Close) 0 ns to 64 us (using the 500 MHz master clock)
Phase and Window Timing Resolution 1 ns, using the 500 MHz master clock
Capture Modes (per channel) Mask
Opening edge of Window
Closing edge of Window
Window – data is valid for entire window duration
Drive/Expect Mode Output: Drive Hi, Drive Lo, Hi-Z
Expect: 1, 0, OK, between states, or mask
Keep last
Toggle last
Accumulate CRC-16
Error Address Record Record address for memory errors
1K deep error memory
Drive Level Range -14 V to +26 V
Drive Voltage Level Range Min: 0.5 V p-p
Max:  26 V p-p
Drive Voltage Accuracy ± 25 mv, < 26 V p-p drive voltage
Sense Level Range -16 V to +22 V
Maximum Sense Voltage Range 26 V
Sense Voltage Resolution 16 bits
Pull-Up/Pull-Down Current Source/Sink ± 24 ma, programmable on a per channel basis
V commutate: -16 to +22 V., programmable on a per channel basis
Pull-Up/Pull-Down Current Source/Sink Accuracy ± 250 uA
Pull-Up/Pull-Down Current Source/Sink Resolution 16 bits
Trigger/Clock Signals (4) Aux signals for external triggering, clocking of digital subsystem, accessible via the receiver interface and the IIP
Mainframe Specifications
Input AC Power 120 / 208 VAC nominal, 3 phase, 5-wire wye configuration
20 A per phase, 47 to 63 Hz,
Input voltage range: 100 / 170 to 155 / 264 VAC
HV Input AC Power Configuration 230 / 400 VAC nominal, 3 phase, 5-wire wye configuration
10 A per phase, 47 to 63 Hz,
input voltage range: 223 / 380 to 310 / 528 VAC
Total Available DC Power PXI voltages: 800 W
Pin electronics: 4.4 KW
PXI Power
+5 V
+3.3 V
+12 V
-12 V
Note: Total output power cannot exceed 800 W.
60 A (max)
60 A (max)
25 A (max)
5 A (max)
Pin Electronics (via P5 connector)
VCC
VEE
3.3 V
+2 V to +30 V, @ 50 A
-4 V to -18 V, @ 80A
3.3 V @ 60 A
Power Supply Monitoring Monitored voltages: 3.3, 5, +12, -12, VIO value
Accuracy: ± 2% of reading
Temperature Monitoring Per slot monitoring, 1 reading/sec/slot
4 second moving average value
User selectable alarm criteria:

  • Maximum slot temperature
  • Average slot temperature

Accuracy: ± 2 °C
Default warning and shutdown limits: +50 °C & +70 °C
Warning and shutdown limits programmable via software driver
Status: Query via software driver and audible alarm for a warning limit condition

PXI Triggers Slots: 2 – 20
Number: 8 per segment
Software controlled segment mapping supports:

  • Isolate a trigger line within a segment
  • Map a trigger line left to right
  • Map a trigger line right to left
PXI Clock Integrated 10 MHz PXI clock with auto-detect function. Presence of an external 10 MHz PXI clock will disable the internal clock. PXI clock is distributed to all peripheral slots.

  • 10 MHz PXI clock accuracy: ±100 ppm
  • External input: Rear panel (TTL compatible) or via timing slot
  • Output: Rear panel, (TTL compatible)
Slots 20 PXI or cPCI Slots (19 instruments max)
Weight (core system) 100 lbs
Overall Dimensions 10U (17.5″) H x 19″ W x 24″ D
Cooling Eight 100 CFM fans for system cooling. Integrated temperature monitoring via an on-board microcontroller with audible and software notification when preset temperature limits are exceeded. Fan speed control and monitoring is automatic and can be controlled / monitored via the GxChassis software.
Environmental and Compliance
Operating 0 °C to +50 °C
Storage -20 °C to +60 °C
Relative Humidity (operating) 5% to 80% RH,non-condensing
Relative Humidity (non-operating) 5% to 95% RH,non-condensing
Altitude (operating) Up to 2000 M
CE Compliance EN61010-1 (pending)
EN61326 (pending)

Note: Specifications are subject to change without notice.

A component of the GENASYS platform, the GX7017 offers the flexibility to incorporate the GENASYS switching subsystem with 3U and 6U PXI instrumentation in one compact, PXI chassis. Based on the 6U PXI architecture, the GX7017 can accommodate up to 9 GENASYS switch cards and 10 PXI modules, with 8 PXI slots supporting the GENASYS GX5960 digital subsystem. Up to 64 external resources can be connected to any of the test system’s switching resources / receiver I/O pins via a high performance, internal 16 wire matrix bus.

The GX7017 chassis incorporates the MAC Panel 6U SCOUT receiver. The SCOUT receiver offers a reliable and high performance method to connect the switch modules to a mass interconnect receiver, minimizing the need for cable assemblies. The SCOUT receiver is a “pull-through” design, with each switch card providing a “cable-less” connection to the receiver connectors – eliminating the need for cable harnesses and the associated reliability issues that come with cabled solutions. The result is a system interconnect design that is cost effective, reliable, and maintainable. The modular design of the SCOUT also allows for the use of a broad range of receiver connectors including high density, high current, and coaxial types. The 6U SCOUT receiver can accommodate up to 21 connector slots and over 8000 connections when fully populated.

Features

The GX7017 is a 20-slot 6U PXI chassis that can accommodate up to 19 switching or instrument cards as well as a remote PXI bus interface such as the MXI-4. In addition to supporting all of the PXI-1 resources, the GX7017’s PXI backplane provides an internal, high performance, 16 wire, analog bus via the backplane’s P5 connectors. Each of the GENASYS switching cards connects to this internal 16 wire bus, providing the ability to route signals from an external instrument to any of the receiver’s interface connections.

System power for the GX7017 includes an 800 W power supply for PXI modules and a supplemental 4.4 KW supply for the digital subsystem’s VCC and VEE rails via the J5 connector located on the PXI backplane. The chassis utilizes a Smart power system which automatically adjusts the VCC and VEE voltages based on the programmed drive-high and drive-low levels of the digital instruments, minimizing power dissipation and overall cooling requirements.

To ensure adequate cooling, the GX7017’s cooling system includes 8, 100 cfm fans, with four located under the card cage and four located at the rear of the chassis, providing positive airflow per the PXI specification and high capacity cooling for PXI modules. This cooling configuration, in conjunction with air plenums within the chassis, provides airflow for all module slots and requires no additional rack space for inlet or outlet air. Additional cooling with dedicated fans is provided for the system power supplies which are located at the rear of the chassis.

The GX7017 chassis supports the monitoring of slot temperatures and system power supply voltages as well providing the ability to program or map each PXI trigger line from one PCI segment to another. In addition, the user can program the temperature monitoring function for specific warning and shutdown limits. All user specific setups can be stored in non-volatile memory as a user configuration and can be used as the default setup for normal chassis operation.

Configuration

The GX7017’s Slot 1 is dedicated for the system controller. A PXI Star Trigger controller, any PXI or cPCI instrument or a GENASYS switching module can be used in slot 2. Slots 3-15 support the PXI Star Trigger, or any PXI or cPCI instrument. GENASYS switching cards can be installed in slots 2-10. Slots 11 and 12 can accommodate cPCI or PXI modules and slots 13 – 20 can accommodate the GX5960 GENASYS digital modules or PXI modules.

Switching Subsystem

The modular architecture of the GX7017 allows the switching subsystem to support a wide range of configurations and capabilities. Input analog signal routing is supported by the GX6032, a matrix switch module which is located on the rear of the chassis. This module is configured as a 32 x 16 matrix and supports up to 32 inputs which can be connected to the GX7017’s internal 16 wire bus. The chassis can accommodate up to (2) 32 x 16 GX6032 modules. Signal routing from the internal backplane to the receiver interface is supported by any of the GENASYS switch cards which are extended 6U PXI modules with direct connection to the receiver interface. One GX6032 module is supplied with the core system.

Digital Subsystem

The GX7017 can accommodate up to (8) GX5961/GX5964 digital subsystem cards, providing a high-performance and compact functional test platform for mixed-signal test applications. The GX5960 offers real-time digital stimulus, record, or expect data modes on all I/O channels. Pattern memory depth is 256K words. Each channel can be configured as an input or output on a per cycle basis. Six drive data formats are supported: NR, R1, R0, RZ, RC, and Complement Surround – providing flexibility to create a variety of bus cycles and waveforms to test board and box level products.

Software

The GX7017 is supported by three software packages: GxChassis to monitor and control the chassis and GxSW to control and display the switching connections, and GtDio6x to control and monitor the digital I/O subsystem including the GX5961 and GX5964 boards. The GxChassis Virtual Panel can be used to interactively set /display shutdown and alarm conditions based on defined temperature levels, set the PXI trigger lines and control the fan speed and monitor the power supply voltage. The GxSW Virtual Panel can be used to interactively connect, disconnect and display the switching connections, perform BIT, view relay usage count and more.
High level switching software – SwitchEasy allows you to display, control and manage overall signal routing and provides end to end signal routing by having the user simply define the resource and receiver pin or UUT connections, simplifying overall application development and deployment time.
Both software packages includes 32/64-bit DLL driver libraries and documentation. The virtual panel can be used to In addition, an API is supplied that supports a variety of programming tools and languages such as ATEasy, Microsoft® Visual Basic, C# and C/++, LabView and LabWindows/CVI and more.

Applications

  • GENASYS switching subsystem
  • Automated system test applications
  • High I/O count, mixed-signal test applications

Enjoy:

Send Enquiry For:

GX7017 Series

Israel's Leading Businesses Choose DCT

Israel's Leading Businesses Choose DCT

DCT’s Skilled Management Team has more than twenty-five years of experience and expertise in the local business environment, coupled with a highly motivated group of employees, positions us as the preferred supplier among the major customers in the industry.

DCT Competitive Edge is the prompt response to our customer needs, the online and on-site direct technical support, professional consulting for the best cost/performance solution, on-time delivery, long-term maintenance, and support.

We can get back to you!

Need a Rugged Device?

Fill in the form!

A variety of tablets are available for all use cases.
- only solutions - No obligations -

Our experts can help you find just about anything.

What Were You Looking For? Let us help.