GX6021 Specifications
Matrix Configuration | Four 1 x 4 multiplexers |
Number of channels | 20 |
Relay Specification | |
---|---|
Contact Resistance | < 0.2 Ω |
Switching Voltage | 200 VDCÂ (max) resistive load |
Switching Current | 0.5 A (max) resistive load |
Operate Time | 6 ms (max) |
Release Time | 3 ms (max) |
RF Specification | |
Impedance | 50 Ω |
Bandwidth | > 300 MHz (-3 dB) |
Insertion Loss | < 0.7 dB at 100 MHz |
Crosstalk Across Groups (50 ohm Terminator) |
10 MHz < -40 dB 100 MHz < -40 dB 200 MHz < -35 dB |
Isolation Between Channels (50 ohm Terminator) |
10 MHz < -40 dB 100 MHz < -40 dB 200 MHz < -35 dB |
VSWR (50 Ohms Terminator) |
1.2:1 at 100 MHz |
Power Requirements | |
Power Consumption +3.3 V +5 V |
100 mA (max) 1 A |
Operating Voltage | +5 VDC |
Environmental | |
Operating Temperature | 0 °C to +50 °C |
Storage Temperature | -20 °C to +70 °C |
Vibration | 5 G at 500 Hz |
Shock 1/2 Sine | 5 G for 6 mS |
Physical | |
Size | 3U PXI |
Weight | 1.1 lbs |
Note: Specifications are subject to change without notice.