GX2065

6.5 Digit DMM / Digitizer PXI Card

  • Full featured 6.5 digit DMM
  • 3 MHz isolated digitizer with memory
  • AC True RMS measurements, 10 Hz to 300 KHz
  • Measure 1 uV to 300 V
  • 7 resistance ranges, 100Ω to 100 MΩ
  • Additional IVI-C (DMM) compatible driver
  • Additional Signametrics SMX2040 & SMX2060 compatible drivers
  • Extended temperature range option
  • PXI hybrid slot compatible
Send Enquiry

GX2065 Specifications

General Specifications
Inputs Hi, Lo, Hi Sense, Lo Sense; floating and isolated from ground
External trigger
Input Connectors (4) Banana, 6-pin DIN
Format PXI, 3U single slot, hybrid slot compatible
DMM and Digitizer Measurement System Features
Resolution 22 bits (DMM),
16 bits (digitizer / DAQ)
DMM Sampling Rate
(VDC, IDC & R Measurements)
Selectable PLC rate, 0.002 to 10;
PLC can be set to 50 or 60 Hz
DMM Reading Rate
(VDC, IDC & 2WR (< 10 M ohm))
5 readings/sec @ 6.5 digits, 60 Hz, (10 PLC), Auto Zero Off
50 readings/sec @ 6.5 digits, 60 Hz, (1 PLC), Auto Zero Off
500 readings/sec @ 5.5 digits, 60 Hz, (0.1 PLC), Auto Zero Off, 1K samples into buffer
2500 readings/sec @ 4.5 digits, 60 Hz, (0.01 PLC), Auto Zero Off, 1K samples into buffer
3500 readings/sec @ 3.5 digits, 60 Hz, (0.002 PLC), Auto Zero Off, 1K samples into buffer
Digitizer (DAQ) Clock Rate Programmable to 3 MHz
Range: (3 MS/s) / N, N=1 to 216
Accuracy: 100 ppm
DAQ Measurement Functions AC / DC voltage and current measurements
Digitizer Memory 8192 samples
DMM Memory 1 K samples
DMM Measurement Characteristics
Input Range 100 nV to 300 V
VAC Input Range 3 µV to 425 V (peak), 300 VRMS 10 Hz to 300 kHz, AC or DC coupled
Crest Factor (VAC) No limitation as long as maximum input signal is below the peak range value.
VDC / VAC Input Impedance > 10 GΩ (0.1, 1, and 10 VDC ranges)
400 pF shunt capacitance
10 MΩ for other AC / DC ranges,
400 pF shunt capacitance
Maximum Input (Volt – Hertz) 8 x 10e7 V x Hz Common Mode Input
8 x 10e7 V x Hz (across Hi or Lo input relative to earth ground)
Input Isolation CATII 300 V
Input Overvoltage Protection 250 V for current input,
300 V CATII for all other inputs
Noise Rejection VDC: 90 dB, NMRR; 140 dB CMRR 15 readings/s, 1 PLC, 6.5 digit, 10 V range
VAC: 70dB, CMRR
IDC Input Range 10 nA to 2 A
IAC Input Range 3 µA to 2 A peak, AC coupled
10 Hz to 5 kHz
Crest Factor (AC Current) No limitation as long as maximum input signal is below the peak range value
AC / DC Input Current Protection 2 A, 250 V, fast blow, sand filled, 1.5 kA breaking
Resistance Range 100Ω to 100 MΩ
Resistance Measurement Configuration Selectable, 2-wire or 4-wire
Burden Voltage 20 mA range, < 0.2 V
100 mA range, < 0.1 V
1 A range, < 0.5 V
2 A range, < 1.0 V
Internal Temperature Measurement Accuracy ± 2°C
Time Base Accuracy 100 ppm
Triggering
Trigger Source Function: Start measurement
Source: PXIbus, software, continuous, external input (DIN connector), timer
Trigger Output Modes Functions: Start of measurement, end of measurement
Trigger can be routed to the PXIbus or the DIN connector
Trigger Input Voltage Range 3.3 V CMOS, 5 V Tolerant
Minimum Trigger Input Pulse Width 50 ns for PXI bus, 250 µs for external DIN input
Trigger Input Impedance 4.75 kΩ
Trigger Input Edge Selectable, positive or negative
AC Measurement Performance
Reading Rate Signal Bandwidth
1 S/s 4 Hz to 4 kHz
5 S/s 20 Hz to 20 kHz (default)
375 S/s 300 Hz to 300 kHz
DC Voltage Measurement
Range Resolution     Accuracy
24 Hours 23°C ±5°
(% of Reading)+
(% of FS)
Accuracy
90 Days 23°C ±5°
(% of Reading)+
(% of FS)
Accuracy
1 Year 23°C ±5°
(% of Reading)+
(% of FS)
100 mV 100nV 0.0030 + 0.0040 0.0040 + 0.0045 0.0045 + 0.0045
1 V 1 µV 0.0030 + 0.0007 0.0040 + 0.0008 0.0045 + 0.0008
10 V 10 µV 0.0010 + 0.0004 0.0025 + 0.0005 0.0030 + 0.0005
100 V 100 µV 0.0030 + 0.0006 0.0050 + 0.0009 0.0060 + 0.0009
300 V 1 mV 0.0030 + 0.0020 0.0045 + 0.0030 0.0060 + 0.0030
DC Voltage Measurement, DAQ Mode
Range Resolution     Accuracy
24 Hours 23°C ±5°
(% of Reading)+
(% of FS)
Accuracy
90 Days 23°C ±5°
(% of Reading)+
(% of FS)
Accuracy
1 Year 23°C ±5°
(% of Reading)+
(% of FS)
100 mV 4µV 0.06 + 0.06 0.06 + 0.06 0.06 + 0.06
1 V 40 µV 0.06+ 0.03 0.06+ 0.03 0.06+ 0.03
10 V 400 µV 0.06+ 0.03 0.06+ 0.03 0.06+ 0.03
100 V 4 mV 0.06+ 0.03 0.06+ 0.03 0.06+ 0.03
300 V 40 mV 0.06 + 0.10 0.06 + 0.10 0.06 + 0.10
DC Current Measurement
Range Resolution     Accuracy
24 Hours 23°C ±5°
(% of Reading)+
(% of FS)
Accuracy
90 Days 23°C ±5°
(% of Reading)+
(% of FS)
Accuracy
1 Year 23°C ±5°
(% of Reading)+
(% of FS)
20 mA 10nA 0.0060 + 0.0030 0.030 + 0.0080 0.0500 + 0.0080
100 mA 100 nA 0.0100 + 0.0300 0.0300 + 0.080 0.0500 + 0.080
1 A 1 µA 0.0200 + 0.0030 0.0500 + 0.0080 0.0800 + 0.0080
2 A 10 µA 0.1000 + 0.0035 0.1200 + 0.0060 0.1200 + 0.0060
DC Current Measurement, DAQ Mode
Range Resolution     Accuracy
24 Hours 23°C ±5°
(% of Reading)+
(% of FS)
Accuracy
90 Days 23°C ±5°
(% of Reading)+
(% of FS)
Accuracy
1 Year 23°C ±5°
(% of Reading)+
(% of FS)
20 mA 4µA 0.03 + 1.0 0.03 + 1.0 0.03 + 1.0
100 mA 40 µA 0.01 + 1.0 0.01 + 1.0 0.01 + 1.0
1 A 40 µA 0.04 + 0.15 0.04 + 0.15 0.04 + 0.15
2 A 80 µA 0.04 + 0.15 0.04 + 0.15 0.04 + 0.15


Notes:
DC measurements @ 10 PLC or 1 PLC with digital filtering
Accuracy of measurement is % of reading + % of Range



AC Volts (RMS), AC Coupled, DAQ Mode
Range (RMS) Range (Vpk) Resolution Frequency and Accuracy [23°C ±5° (% of Reading) + (% of FS)]
50 mV 100 mV 2 µV Frequency Accuracy
24 Hours
Accuracy
90 Days
Accuracy
1 Year
3 Hz – 10Hz 0.5 + 0.28 0.5 + 0.28 0.5 + 0.28
>10 Hz – 20 KHz 0.2 + 0.28 0.2 + 0.28 0.2 + 0.28
>20 KHz – 50 KHz 0.26 + 0.3 0.26 + 0.3 0.26 + 0.3
>50 KHz – 100 KHz 0.75 + 0.33 0.75 + 0.33 0.75 + 0.33
>100 KHz – 300 KHz 4.15 + 0.75 4.15 + 0.75 4.15 + 0.75
0.5 V
5 V
50 V
300 V
1 V
10 V
100 V
450 V
20 uV
200 uV
2 mV
30 mV
3 Hz – 10Hz 0.35 + 0.03 0.35 + 0.03 0.35 + 0.03
>10 Hz – 20 KHz 0.05 + 0.03 0.05 + 0.03 0.06 + 0.03
>20 KHz – 50 KHz 0.11 + 0.05 0.11 + 0.05 0.12 + 0.05
>50 KHz – 100 KHz 0.60 + 0.08 0.60 + 0.08 0.60 + 0.08
>100 KHz – 300 KHz 4.0 + 0.5 4.0 + 0.5 4.0 + 0.5
AC Current (RMS), AC Coupled, DAQ Mode
Range (RMS) Resolution Frequency and Accuracy [23°C ±5° (% of Reading) + (% of FS)]
0.5 A 40 µA Frequency Accuracy
24 Hours
Accuracy
90 Days
Accuracy
1 Year
3 Hz – 10 Hz 0.30 + 0.04 0.30 + 0.04 0.30 + 0.04
>10 Hz – 3 KHz 0.10 + 0.04 0.10 + 0.04 0.10 + 0.04
>3 KHz – 5 KHz 0.14 + 0.04 0.14 + 0.04 0.14 + 0.04
1.0 A 80 µA 3 Hz – 10 Hz 0.35 + 0.09 0.35 + 0.09 0.35 + 0.09
>10 Hz – 3 KHz 0.15 + 0.09 0.15 + 0.09 0.15 + 0.09
>3 KHz – 5 KHz 0.18 + 0.09 0.18 + 0.09 0.18 + 0.09
Resistance
Range (ohms) Open Circuit Voltage &
Test Current
Resolution Accuracy
24 Hours 23°C ±5°
(% of Reading)+
(% of FS)
Accuracy
90 Days 23°C ±5°
(% of Reading)+
(% of FS)
Accuracy
1 Year 23°C ±5°
(% of Reading)+
(% of FS)
100 6.9 V, 1 mA 100µΩ 0.0020 + 0.0060 0.0080 + 0.0060 0.0100 + 0.0060
1000 6.9 V, 1 mA 1 mΩ 0.0025 + 0.0006 0.0085 + 0.0020 0.0105 + 0.0006
10 K 6.9 V, 100 µA 10 mΩ 0.0020 + 0.0006 0.0080 + 0.0020 0.0100 + 0.0006
100 K 12.8 V, 10 µA 100 mΩ 0.0030 + 0.0006 0.0090 + 0.0010 0.0110 + 0.0010
1 M 12.8 V, 1 µA 1 Ω 0.0020 + 0.0006 0.0020 + 0.0010 0.0100 + 0.0010
10 M 7 V, 0.7 µA  // 10 M Ω 10 Ω 0.0150 + 0.0006 0.0200 + 0.0010 0.0400 + 0.0010
100 M 7 V, 0.7 µA  // 10 MΩ 100 Ω 0.0800 + 0.0030 0.2000 + 0.0030 0.2000 + 0.0030
DC Voltage Measurement, DAQ Mode
Range Resolution Accuracy
24 Hours 23°C ±5°
(% of Reading)+
(% of FS)
Accuracy
90 Days 23°C ±5°
(% of Reading)+
(% of FS)
Accuracy
1 Year 23°C ±5°
(% of Reading)+
(% of FS)
100 mV 4µV 0.06 + 0.06 0.06 + 0.06 0.06 + 0.06
1 V 40 µV 0.06 + 0.03 0.06 + 0.03 0.06 + 0.03
10 V 400 µV 0.06 + 0.03 0.06 + 0.03 0.06 + 0.03
100 V 4 mV 0.06 + 0.03 0.06 + 0.03 0.06 + 0.03
300 V 40 mV 0.06 + 0.10 0.06 + 0.10 0.06 + 0.10

 

Diode Measurement
Test Current Voltage Range       Current Source Accuracy Accuracy (Nominal)
24 Hours 23°C ±5°
(% of Reading)+
(% of FS)
Accuracy (Nominal)
90 Days 23°C ±5°
(% of Reading)+
(% of FS)
Accuracy (Nominal)
1 Year 23°C ±5°
(% of Reading)+
(% of FS)
10 uA 0 – 12 V 5% 0.001 + 0.004 0.0025 + 0.005 0.003 + 0.005
100 uA 0 – 6.5 V 5% 0.001 + 0.004 0.0025 + 0.005 0.003 + 0.005
1 mA 0 – 6.5 V 5% 0.001 + 0.004 0.0025 + 0.005 0.003 + 0.005
Frequency Measurement
Frequency Range 1 Hz to 500 KHz
Input Voltage* 20 mV to 300 V
Resolution (offset ppm) 0.33 (1 second gate time)
3.33 (100 mSec gate time)
33.3 (10 mSec gate time)
Accuracy 100 ppm of reading + offset ppm


* Input amplitude must be at least 20% of FS and input amplitude must not exceed specified volt – hertz product.

Environmental and Physical Specifications
Safety Complies with IEC 61010-1, CAT II
300 V, pollution degree 2
EMC Complies with EN61326-1
Calibration Calibration is performed at the factory using NIST traceable instrumentation.
All calibration constants are stored on-board in non-volatile EEROM.
Calibration can be performed by any calibration laboratory with the appropriate equipment.
Calibration Interval: 1 year
Operating Temperature Range GX2065: 0°C to +50°C
GX2065-M: 0°C to +62°C; contact factory for extended temperature range specifications
Storage Temperature Range GX2065:  -20 °C to +85°C
GX2065-M: -51 °C to +85 °C
Relative Humidity Operating: 80% at 40 °C
Storage: 95% at 40 °C
Power (max) +5 VDC, 2.3 A
+3.3 VDC, 255 mA
+12 VDC, 16 mA
-12 VDC, 25 mA
Connectors (4) Banana jacks:
Hi: Voltage, 2 W Ω
Lo: Voltage, Current, 2 W Ω
Sense Hi: Current, 4 W Ω
Sense Lo: 4 W Ω
6-pin DIN: Trigger in, Trigger out, Trigger Gnd

Note: Specifications are subject to change without notice.

The GX2065 offers a unique combination of features, resolution, accuracy and speed in a compact, single slot 3U PXI format. Featuring 6-½ digit resolution, 0.005% basic DCV reading accuracy and up to 3,500 reading per second (rps) assures you of measurements that are accurate, fast and repeatable. All measurement functions including digitizing functions are isolated from the PXI bus – providing the ability to make true differential, floating measurements. An on-board controller performs all necessary DMM and digitizer calculations, minimizing PXI control bus overhead.

Features

The GX2065 is designed as a universal, multifunction DMM and provides all of the features associated with standard bench top DMMs including VDC, VAC, 2 and 4 – wire resistance measurements, and current measurements. Additionally, the GX2065 features a 3 MHz, 16 bit, isolated input digitizer which allows users to acquire and analyze waveforms. Built in analysis and waveform functions include RMS, average, peak to peak, and peak to average measurements. Up to 8192 samples can be stored in the digitizer’s memory. Frequency and period measurements to 500 kHz are also supported. An external TTL trigger via the PXI bus or front panel is available for triggering DMM measurements.

Software

The GX2065 is supplied with the GXDMM software package which includes a virtual instrument panel, a Windows 32/64-bit DLL driver libraries and documentation. The virtual panel can be used to interactively program and control the instrument from a window that displays the instrument’s current settings and status. In addition, interface files are provided to support access to programming tools and languages such as ATEasy, LabView, LabView/Real-Time, C/C++, Microsoft Visual Basic®, Delphi, and Pascal. An On-Line help file and PDF User’s Guide provides documentation that includes instructions for installing, using and programming the board. Signametrics SMX2040 & SMX2060 and IV-C compatible drivers are also supplied, allowing customers to easily interchange other vendors DMMs (for example SMX2040 from Signametrics or PXI-4070 or PXI-4072 from NI) with the GX2065 without changing the application code.
A separate software package – GtLinux – provides support for Linux 32/64 operating systems.

Applications

  • Automated production testing
  • Laboratory automation
  • Portable/field test
  • Semiconductor and component test

Enjoy:

Send Enquiry For:

GX2065

Israel's Leading Businesses Choose DCT

Israel's Leading Businesses Choose DCT

DCT’s Skilled Management Team has more than twenty-five years of experience and expertise in the local business environment, coupled with a highly motivated group of employees, positions us as the preferred supplier among the major customers in the industry.

DCT Competitive Edge is the prompt response to our customer needs, the online and on-site direct technical support, professional consulting for the best cost/performance solution, on-time delivery, long-term maintenance, and support.

We can get back to you!

Need a Rugged Device?

Fill in the form!

A variety of tablets are available for all use cases.
- only solutions - No obligations -

Our experts can help you find just about anything.

What Were You Looking For? Let us help.