DC Bias Current Source 6240A (40A)

DC Bias Current Source 6240A (40A)

  • Provides a maximum output of 40A DC bias current, with up to 320A total using 8 units.
  • Designed for magnetic saturation current (Isat) and temperature rise current (Irms) analysis on inductors.
  • Frequency range of up to 3MHz, ideal for high-frequency applications.
  • Can be controlled via LCR Meter or Impedance Analyzer for precise measurements.
  • Power consumption up to 640W per unit, offering robust performance for demanding applications.
Send Enquiry

Features

  • Up to 3MHz
  • Each individual unit can output DC Bias Current 40A (Max.320A)
  • Control by the LCR Meter or Impedance Analyzer

The 6240A DC Bias Current Source is designed for performing magnetic saturation current (Isat) and temperature rise current analysis (Irms) on inductors. It provides a single output current of 40A. To conduct such analysis, you have the option to purchase the system along with the 6632 Impedance Analyzer.

For the 6632 Impedance Analyzer, it has a frequency range of 100Hz-3MHz and can handle a maximum output current of 320A using 8 units.

The 6240 will be discontinued on 2025/12/31 (service continues for 5 years). Replacement models: 6240A.

Application

Ferromagnetic materials (like iron) are composed of microscopic regions called magnetic domains. The stronger the external magnetic field H, the more the domains align, yielding a higher magnetic flux density B. Eventually, The magnetization remains nearly constant, and is said to have saturated. The domain structure at saturation depends on the temperature.

What is magnetic saturation?

In electronic circuits, transformers and inductors with ferromagnetic cores operate nonlinearly when the current through them is large enough to drive their core materials into saturation. This means that their inductance and other properties vary with changes in drive current. In linear circuits this is usually considered an unwanted departure from ideal behavior.

 

Magnetic saturation current is called Isat, and the temperature rise current is called I rms. When the transformer and the inductor pass a large current in the actual circuit operation, the magnetic field of the magnetic core will produce magnetic saturation, which will cause the inductance characteristic to decline. Therefore, the R&D engineer will set the current value of the inductance reduction allowable range.

Option 6632+6243 DC Bias Curretnt Test System

Supports magnetic saturation current analysis measurement function.

Isat (Magnetic saturation current curve)

Irms (Rated current curve)

Using a DC Bias current source to apply a 200A bias current to the inductor, the inductance decreased from 2.06983uH to 1.02845uH.

Equivalent Circuit Analysis (Option)

It has seven different models, combine with different types of parameters ( R, L, C) help customers model the impedance versus frequency characteristics and self-resonant frequency (SRF).

Magnetic Material Test Fixture (FX-0000C8)

Using the magnetic material test fixture for measuring of permeability of various toroidal cores or ferrite cores and electromagnetic shielding coating materials, 6632 built-in formula to directly calculate the permeability coefficient value μr.

List Mode

50 groups of list mode setting (Each group contains up to 15 steps).

MICROTEST DC Bias Source Test System provides precise verification of magnetic components’ magnetic saturation current (Isat) and temperature rise current (Irms). It is equipped with a DC bias current source integrated with an LCR meter/Impedance Analyzer and can be configured as a desktop unit or integrated into a testing cabinet. Operation settings and test results are displayed on the LCR meter/Impedance Analyzer and can also be accessed through PC connection software.

The DC bias current output ranges up to a maximum of 640A/120A/60A/20A, with frequency responses of 100Hz-30MHz/10MHz/3MHz.

For research and development (R&D) or scientific research institutions, there is the option of the 6632+ / 6632S+ series, which includes a current curve sweep analysis feature.

For production lines, the 6350+ series is available as an option.

Specifications

 

Model 6240A
DC Bias Current Max. 320A
units of the DC Bias 8
Power consumption 640W Max.
Output Current (unit) 40A

The DC Bias Source 6240 will be discontinued on 2025/12/31 (service continues for 5 years)

Replacement models: 6240A

Option LCR Meter/Impedance Analyzer Frequency Response
6632 100Hz-3MHz

DC Bias Current Source 6240A
 Accuracy (6632) 0.000A-1.000A 1%+5mA
1.001A-5.000A 2%
5.001A-20.000A 3%
DCR Test
Constant power output
Current switch

System

   Power Supply Voltage:88-264Vac
Frequency:47-63Hz
  Environment Temperature:10℃-40℃
Humidity:20-90%RH
Dimension 356x145x525 mm (W*H*D)/6240A/6240
  Weight 20 Kg (6240A)
Display
Interface RS-232、Handler

Accessories

Standard Accessories

  Power Cord
  DIP Test Fixture-DC Bias Current  (F6210)

Optional Accessories

  PC Link Software
  SMD Test Fixture-DC Bias Current  (F6220)
  BNC+BNC cable

Enjoy:

Send Enquiry For:

DC Bias Current Source 6240A (40A)

Israel's Leading Businesses Choose DCT

Israel's Leading Businesses Choose DCT

DCT’s Skilled Management Team has more than twenty-five years of experience and expertise in the local business environment, coupled with a highly motivated group of employees, positions us as the preferred supplier among the major customers in the industry.

DCT Competitive Edge is the prompt response to our customer needs, the online and on-site direct technical support, professional consulting for the best cost/performance solution, on-time delivery, long-term maintenance, and support.

We can get back to you!

Need a Rugged Device?

Fill in the form!

A variety of tablets are available for all use cases.
- only solutions - No obligations -

Our experts can help you find just about anything.

What Were You Looking For? Let us help.