Alarms and Errors
When any of the following errors occurs, the item(s) of the error(s) and red
Alarm symbols will be displayed on CIW (Control Information Window).
The possible alarms that the CSA may encounter are described in Table 2-4,
and the tab of this table will be Err Sec under ADSL configuration.

Figure 2-6 Alarm and Error in the LINK QUALITY tab

Table 2-4 Alarm descriptions

ItemDescription
FECSForward Error Correction Second: The occurrence of one-second intervals with one or more FEC errors.
ESErrored Second: The occurrence of one-second intervals with one or more CRC-8, LOS, SEF defects, or LPR defects.
SESSeverely Errored Second: The occurrence of severely errored seconds (SES).An SES is declared if, during a one-second interval, there are 18 or more CRC-8, LOS, SEF, or LPR defects.
LOSSLoss of Sync Second: The occurrence of one-second intervals with one or more LOS defects.
UASUnavailable Second: The occurrence of one-second intervals for which the xDSL line is unavailable. The xDSL line becomes unavailable at the onset of 10 contiguous SES, and they shall be included in unavailable time.

האם ניתן להתקין אקרובט על המכשיר? תשובה: לא

אבטחה. המוצר עובד על מערכת לינוקס שעברה קסטומיזציה וחסינה בפני וירוסים.

כרטיס זיכרון. המוצר מגיע עם 256 ק”ב. ניתן להתקין כרטיסים גדולים יותר (פחות מ-1 גיגה) בתיאום ובאישור מראש עם הספק היות ויכולות להיות בעיות בנושאי כתיבה לכרטיס הזיכרון.

שמירת קונפיגורציה כברירת מחדל. יש להפסיק את פעולת המכשיר בכל הלשוניות
( NET CLIENT, xDSL CONTROL and IP TEST ). לאחר מכן יש ללחוץ על CONFIG ו-SAVE AS