GX1034 Specifications
General | |
---|---|
Source / Measure Channels | Meas Hi, Meas Lo Sense Hi, Sense Lo |
Source / Measure Connector | DB-9, female |
10 MHz Reference Connector | BNC front panel and PXI backplane connector |
Format | PXI, 3U single slot, compatible with PXI Express hybrid slots |
DC Voltage Source Standard | |
Output Voltage | ±9.0, ±0.9, ±0.09, ±0.009 V |
Accuracy | ±9.0 V: ±0.005% ±0.9 V: ±0.005% ±0.09 V: ±0.016% ±0.009 V: ±0.1% |
Temperature Coefficent | 0.6 ppm / °C |
Long Term Drift | 6 ppm for 1000 hours |
Output Divider | Resistive series network (Ohms): 10 k, 1 k, 100, 10 |
AC Voltage Source Standard | |
Output Voltage | 3.5, 0.35, 0.035, 0.0035 VAC, nominal All voltages support the following frequencies: 50 Hz, 60 Hz, 100 Hz, 400 Hz, 1 kHz, 10 kHz, 100 kHz |
Accuracy 50 Hz, 60 Hz, 100 Hz |
3.5 VAC: ±0.6% 0.35 VAC: ±0.6% 0.035 VAC: ±0.6% 0.0035 VAC: ±4% |
Accuracy 400 Hz, 1 kHz |
3.5 VAC: ±0.6% 0.35 VAC: ±0.6% 0.035 VAC: ±0.6% 0.0035 VAC: ±4.75% |
Accuracy 10 kHz |
3.5 VAC: ±0.6% 0.35 VAC: ±0.6% 0.035 VAC: ±0.6% 0.0035 VAC: ±5% |
Accuracy 100 kHz |
3.5 VAC: ±4% 0.35 VAC: ±4% 0.035 VAC: ±4% 0.0035 VAC: ±9.5% |
Temperature Coefficient | 3 ppm / °C (voltage reference) |
Long Term Drift | 6 ppm for 1000 operating hours |
Frequency Accuracy | ±0.1 ppm |
Output Divider | Resistive series network (Ohms): 10 k, 1 k, 100, 10 |
Resistor Standards | |
---|---|
1 Ohm | ±0.06%, 3 ppm / °C, 4-wire |
10 Ohm | ±0.012%, 0.2 ppm / °C, 4-wire |
100 Ohm | ±0.01%, 0.2 ppm / °C, 4-wire |
1 kOhm | ±0.004%, 0.2 ppm / °C, 2-wire |
10 kOhm | ±0.004%, 0.2 ppm / °C, 2-wire |
100 kOhm | ±0.015%, 5 ppm / °C, 2-wire |
1 MOhm | ±0.0275%, 3 ppm / °C, 2-wire |
10 MOhm | ±0.1%, 2 ppm / °C, 2-wire |
10 MHz Frequency Standard and Divider | |
Output Frequency | 10 MHz |
Initial Accuracy | ±1 ppm |
Drift | 100 ppb / °C (max) |
Output | Front panel BNC: TTL compatible, 50 Ohm load PXI connector: PXI 10 MHz clock |
10 MHz Divider Output | 24-bit resolution, programmable |
DC Current Source | |
Range | 0 – 19.9 mA 16-bit resolution, programmable |
Accuracy | ±0.025 mA of programmed value |
Compliance | 0 V – 12.5 V |
DC Voltage Measurement | |
Resolution | 16-bit |
Mode | Differential |
Input Impedance | 20 kOhm nominal |
Range | -10 V to +10 V |
Accuracy | ±0.025 V of reading |
Power | |
+5 V | 1 A (max.) |
+12 V | 500 mA (max.) |
+3.3 V | 500 mA (max.) |
Configuration | |
Weight | 210 g |
Size | 3U, single slot, hybrid slot compatible |
Environmental | |
Operating Temperature | 0 °C to +50 °C |
Storage Temperature | 0 °C to +70 °C |
Humidity | 10% to 80% (Non-condensing) |
Safety | EN61010-1:2001 |
CE Labeled | Yes EN61000-6-1:2001, EN55011:1998 |
Calibration Interval | 1 year |
Note: Specifications are subject to change without notice.