DCT | Test and Measurement

Welcome to our new site! Feel free to report any issues, contact us at [email protected]

Frequency Counter Intelligent Counter GFC-8131H

Frequency Counter Intelligent Counter GFC-8131H

  • Wide Frequency Range Measures frequencies from 50 MHz to 1.3 GHz, ideal for high-frequency applications.
  • High Accuracy Offers up to 7-digit accuracy for precise frequency and period measurements.
  • Flexible Gate Time Configurable gate times from 10ms to 10s, ensuring both fast response and high accuracy.
  • Advanced Sensitivity Sensitivity of <40mVrms (typical: 10mVrms) on Channel B for detailed measurements.
  • User-Friendly Interface Easy-to-use front panel with clear 8-digit LED display for convenient operation.
Send Enquiry

Specification

Feature Specification
DISPLAY 8 digits with Hz, kHz, MHz, GHz, s, ms, μs, and overflow indicator
GATE TIME Variable from 10ms to 10s, or 1 period of input depending on whichever is greater
ACCURACY ±(resolution ± timebase error)
CHANNEL A Range: DC coupling: 0.01Hz ~ 120MHz, AC coupling: 30Hz ~ 120MHz
Sensitivity: 10mV typical, 50mV maximum
Coupling: AC or DC, selectable
Filter: Low pass, selectable in or out for channel A (-3dB point, nominal 100kHz)
Impedance: 1MΩ // 40pF
Attenuator: 1/1 or 1/20dB
Trigger Level: -2.5VDC ~ +2.5VDC
Adjustment Resolution: 100nHz for 1Hz input, 0.1Hz for 100MHz input (Frequency); 10ns for 1Hz, 0.1×10⁻¹⁵s for 100MHz (Period)
Display Accuracy: 7 digits for 1 sec gate time, 6 digits for 100ms gate time, 5 digits for 10ms gate time
Period Range: 8ns ~ 100s (at least 7 digits displayed per gate time)
CHANNEL B Range: 50MHz ~ 2.7GHz (GFC-8270H), 50MHz ~ 1.3GHz (GFC-8131H)
Sensitivity: <50mVrms (10mVrms typical) for GFC-8270H, <40mVrms (10mVrms typical) for GFC-8131H
Coupling: AC only
TIME BASE Aging Rate: 1ppm per month
Temperature: 5ppm, 23°C ± 5°C
Line Variation: 0.005ppm for ±10% variation
POWER SOURCE AC 100V/120V/220V/230V ±10%, 50/60Hz; Power consumption: 15VA max.
DIMENSIONS & WEIGHT Dimensions: 230(W) × 95(H) × 280(D) mm
Weight: Approx. 2.2kg

 

* GFC-8270H has been Discontinued

The GFC-8000 Series performs virtually all of the counting measurements required in laboratories, in terms of both period and frequency. A bright red 8 digit LED display with an included overflow indicator provides a clear view. Both models feature a stable time base with a maximum resolution of 100nHz and 10nS at 1Hz for frequency and period measurement, respectively.

Gate time can be configured for fast response (5 digits/10ms) or accuracy (7 digits/s) for more control. For high frequency needs, the GFC-8270H can operate at up to 2.7GHz. The GFC-8000 Series features easy operation with a simple front panel interface, suitable for both portable and bench-top use.

 

 

 

 

Included Accessories

User manual x1, Power cord x1, GTL-110 x 1, GTL-101 x 1

Enjoy:

Send Enquiry For:

Frequency Counter Intelligent Counter GFC-8131H

Israel's Leading Businesses Choose DCT

Israel's Leading Businesses Choose DCT

DCT’s Skilled Management Team has more than twenty-five years of experience and expertise in the local business environment, coupled with a highly motivated group of employees, positions us as the preferred supplier among the major customers in the industry.

DCT Competitive Edge is the prompt response to our customer needs, the online and on-site direct technical support, professional consulting for the best cost/performance solution, on-time delivery, long-term maintenance, and support.

We can get back to you!

Need a Rugged Device?

Fill in the form!

A variety of tablets are available for all use cases.
- only solutions - No obligations -

Our experts can help you find just about anything.

What Were You Looking For? Let us help.