Features
- Alarm relay contacts provided which can offer the critical, major and minor alarms with audible and visible alarm output
- Auto Laser Shutdown (ALS) to prevent hazardous laser radiation to personnel
- Channel Capacity : 4,8,12 or 16 channels
- Configuration data can be stored into flash buffer to avoid any loss caused by power disruption and will be restored automatically by system
- End to end propagation delay is less than 2 m sec
- Management : Local side can be managed via Keypad, Terminal and Telnet ;
- Remote side can be managed inband via keypad, Terminal, Telnet & optional SNMP
- Modularized interface: G.703 E1 / T1 / Datacom (V.35/RS-449,530/X.21) / Ethernet
- Bridge 10/100Base-T
- Real Time Clock (RTC) run by backup battery to avoid time setting loss caused by power disruption
- Redundant Fiber 1+1 Protection, the switching time between is less than 50 m sec
- Supports BERT