DCT | Test and Measurement

Welcome to our new site! Feel free to report any issues, contact us at [email protected]

EMI Pre Compliance Tester Handyscope HS6 DIFF - 1000XMESG

EMI Pre Compliance Tester Handyscope HS6 DIFF – 1000XMESG

  • Built for EMI Pre-Compliance: Includes TP-EMI-HS6 probe set with H-field and E-field probes to identify interference sources quickly and effectively.
  • High Sampling & Bandwidth: Delivers 1 GSa/s sampling and 250 MHz analog bandwidth on four differential input channels—ideal for high-speed signal capture.
  • Precision & Flexibility: Offers 8–16-bit resolution and 256 Mpoints memory per channel for long-duration, high-detail waveform recording.
  • Advanced Spectrum Analysis: Features 140 dB dynamic range, multi-window FFT, limit line overlays, and selectable amplitude units (dBµV, dBm).
  • Safe and Portable: USB-powered design with SafeGround protection, tripod mount, and a robust carry case for convenient field use.
Send Enquiry

The powerful capabilities of the Handyscope HS6 DIFF – 1000XMESG EMI analyzer give the user the possibility to quickly perform a good EMI compliance test. With this cost effective test, time and money are saved by avoiding extra visits to expensive EMC testing facilities. The supplied EMI probe set TP-EMI-HS6 contains three magnetic field (H field) probes and one electric field (E field) probe. The tripod ensures that the probes can be positioned properly at the object under test.

Above: a total spectrum from 0 Hz to 500 MHz and 3 displays with magnified parts of the live spectrum. Below: the total time domain signal and a magnified part of the time domain signal, live with the spectrum.

Figure 2: Above: a total spectrum from 0 Hz to 500 MHz and 3 displays with magnified parts of the live spectrum. Below: the total time domain signal and a magnified part of the time domain signal, live with the spectrum.

 

The Handyscope HS6 DIFF – 1000XMESG EMI analyzer has a very low resolution bandwidth of up to 7.45 Hz (at a span of 500 MHz), which is unique in its class. As a result, details in each part of the spectrum can be analyzed thoroughly.

Note: A resolution bandwidth of 7.45 Hz at a span of 500 MHz gives a total of 67,108,864 spectral components. When your display is 1920 pixels wide, you require 34,952 displays to show the full spectrum 1:1. 34,952 displays with a width of 50 cm (23 inch diagonal) each, gives a total display width of 17.47 km (10.85 mile)! Therefore, if you zoom in 35,000 times, you will get the spectral components 1:1 on your display. That is exceptional for an EMI analyzer and it makes each frequency component very well visible.

The large dynamic range of 140 dB allows the measurement of a wide variety of interference frequencies. Standard limit lines according to EN61326-1:2006/EN55011:2007 can be switched on or off. The resolution bandwidth and frequency range can be selected individually.

Combilog Antenna
Figure 3: Combilog Antenna

There are three operating modes: Normal, Average and Max Hold. Normal mode displays the spectrum of the source trace. Averaging mode is effective in reducing the noise of the signal, to see more of the harmonic or carrier detail. You can select the number of spectra to be averaged. Max Hold displays the maximum level that the signal reaches and is useful for frequency measurements where it shows the history of peak values across the frequency axis. Averaging and Max Hold history can be cleared manually to start a new measurement.

With the extensive marker capabilities in the graph, various aspects of the spectrum can be measured.

The amplitude unit can be set to dB, dBv, dBmV, dBµV, dBµV (at 10m) and dBm. The amplitude range can be set to one of three ranges: 0 to 100 dBµV, 20 to 120 dBµV or 40 to 140 dBµV. For accurate amplitude measurement, a flat top window is used by default. Besides the flat top window, eight other windows can be selected from.

The EMI analyzer can also be used as normal spectrum analyzer. With a biconical antenna or Combilog Antenna a spectrum of 10 MHz to 500 MHz can be measured.

Figure 4 shows a spectrum measured with a Combilog antenna which was placed outside. Next to the full spectrum from 0 Hz to 500 MHz, there is also a view with the FM band of 87.5 MHz to 108 MHz, an FM radio station at 92.2 MHz and even an AM radio station at 1600 kHz. The time domain signal is also shown, as well as a zoomed in part of the time domain signal. All windows are real time and correlations between different frequencies and the time domain signal can be conveniently viewed. The multi window feature of the EMI analyzer offers the user unlimited analysis and display capabilities.

Using the Quick Setup button, the EMI analyzer can be controlled fast and easy.

Figure 4: Using the Quick Setup button, the EMI analyzer can be controlled fast and easy.

The TiePie Handyscope HS6 DIFF – 1000XMESG is a specialized USB oscilloscope designed to excel as an EMI pre-compliance analyzer, offering capabilities far beyond conventional scopes or standard spectrum analyzers. It allows engineers to perform cost-effective EMI diagnostics early in the design cycle—minimizing development delays and reducing the need for repeated visits to expensive EMC labs.

Equipped with a comprehensive TP-EMI-HS6 probe set (three H-field probes, one E-field probe, tripod, and accessories), the HS6 DIFF enables pinpoint identification of radiated emissions from PCBs, cables, and enclosures. The analyzer’s multi-window FFT function allows simultaneous visualization of the entire spectrum (up to 500 MHz) and magnified frequency bands, providing a clear view of both broad and narrowband interference.

Unlike traditional spectrum analyzers with single-display limitations, this oscilloscope displays multiple live spectrum and time-domain views in parallel. Users can correlate frequency peaks with their time-domain sources—critical for understanding transient or modulated noise.

The instrument boasts an exceptionally low resolution bandwidth of 7.45 Hz (across a 500 MHz span), offering over 67 million spectral points, making even the smallest emissions distinguishable. Its 140 dB dynamic range ensures that both strong and weak signals are captured with high fidelity.

Users can apply standard compliance limit lines (EN55011/EN61326), select amplitude units (dBµV, dBm, dBmV), and choose from several window functions for accurate EMI measurements. Modes like Normal, Average, and Max Hold enhance noise visibility and trend analysis.

Portable, USB-powered, and equipped with SafeGround technology for secure differential and grounded measurements, the HS6 DIFF is an indispensable tool for R&D teams seeking in-depth, real-time EMI analysis without the need for costly, full-lab spectrum analyzers.

  • Input Channels: 4 (differential)
  • Bandwidth: Up to 250 MHz
  • Sampling Rate: 1 GSa/s max
  • Resolution: 8–16 bits
  • Memory Depth: 256 Mpoints per channel
  • FFT Resolution Bandwidth: As low as 7.45 Hz
  • Dynamic Range (Spectrum): 140 dB
  • Amplitude Units: dB, dBv, dBmV, dBµV, dBm
  • Compliance Standards: EN55011:2007 / EN61326-1:2006
  • Input Coupling: DC
  • Time Base Accuracy: 1 ppm
  • Interface: USB
  • Included Accessories: 3 H-field probes, 1 E-field probe, SMA/BNC cables, tripod, terminator, carry case
  • Warranty: 2 or 5 years depending on model
  • TP-NFP-25 H field probe: 25 mm diameter, SMA connector
  • TP-NFP-15 H field probe: 15 mm diameter, SMA connector
  • TP-NFP-5 H field probe: 9 mm diameter, SMA connector
  • TP-NFP-E9 E field probe: 2 mm tip, SMA connector
  • Tripod TP-3P-15: up to 18 cm high
  • Antenna cable TP-BNC-SMA-200: flexible, 200 cm long, SMA to BNC
  • Antenna cable TP-SMA-20: semi flexible, 20 cm long, SMA to SMA
  • Grounded 50 Ohm BNC terminator TP-BNC-T50G: BNC to BNC, 5 cm ground lead with 2 mm banana plug
  • Carry case BB251: 255 x 210 x 60 mm

Enjoy:

Send Enquiry For:

EMI Pre Compliance Tester Handyscope HS6 DIFF – 1000XMESG

Israel's Leading Businesses Choose DCT

Israel's Leading Businesses Choose DCT

DCT’s Skilled Management Team has more than twenty-five years of experience and expertise in the local business environment, coupled with a highly motivated group of employees, positions us as the preferred supplier among the major customers in the industry.

DCT Competitive Edge is the prompt response to our customer needs, the online and on-site direct technical support, professional consulting for the best cost/performance solution, on-time delivery, long-term maintenance, and support.

We can get back to you!

Need a Rugged Device?

Fill in the form!

A variety of tablets are available for all use cases.
- only solutions - No obligations -

Our experts can help you find just about anything.

What Were You Looking For? Let us help.