DCT | Test and Measurement

Welcome to our new site! Feel free to report any issues, contact us at [email protected]

Single-Phase Power Meter 7120

Single-Phase Power Meter 7120

  • Dual AC/DC Meter Measures both AC and DC power with a wide range from 0.001W to 16kW, covering various applications.
  • High Precision Standby power detection with a D.P.I. of 0.001W for accurate low-power measurements.
  • Crest Factor Display Shows crest factor ratio and supports a maximum current crest factor of CF9 for detailed analysis.
  • Harmonic Wave Analysis Analyzes up to 50 levels of harmonic waves, providing in-depth power quality insights.
  • Data Storage Stores up to 1000 sets of measurement data, enabling easy tracking and analysis of power usage over time.
Send Enquiry

  •  AC / DC Dual amp/watt-hour meter
  • Wide range 0.001W-16KW
  • Connection software attached
  • Standby Power D.P.I. of 0.001W
  • With crest factor ratio display
  • Up to the 50 levels harmonic wave analysis capability
  • 1000 sets of measurement data storage space
  • Current crest factor is highest CF9

The MICROTEST 7120 Power Meter is a high-precision instrument designed for detailed power analysis across a broad frequency range of 15Hz to 100kHz. It supports 0th order harmonic analysis, allowing for the assessment of power quality and waveform characteristics. With a maximum crest factor of 9 (CF9), it can effectively measure and analyze high-current waveforms, making it suitable for testing both AC/DC and DC/DC power products.

This versatile power meter can measure key electrical parameters such as power, voltage, current, power factor, and phase, providing comprehensive insights into power system performance. It is ideal for applications that require detailed power analysis, including testing power supplies, energy efficiency, and power conversion systems. The MICROTEST 7120 is designed for use in both R&D and production environments, delivering reliable and accurate measurements to ensure optimal performance and compliance with industry standards.

Specifications

Selection

Model 7110 7120
Frequency Range DC, 15Hz~10KHz DC, 15Hz~100KHz
Harmonic (option) ● / – ● / –

 

Measurement Parameters

Parameters Range Parameters Range
Vrms 0.1V ~ 600V PF 0.000 ~ ±1.000
Vdc 0.1V ~ 600V Deg -180°~ +180°
Irms 0.1mA ~ 20A THD 0.01% ~ 99.99%
Idc 0.1mA ~ 20A Hz 15Hz ~100kHz
W 0.01W ~16KW

 

Measurement Range

Current (fixed/Auto) 0.01A0.03A0.1A0.3A1A3A10A20A
Voltage (fixed/Auto) 10V30V100V300V600V

 

Harmonics SPEC

Analysis base To achieved stable fundamental frequency analysis by voltage or current (non-inverter)
Frequency Range 45Hz 45Hz – 440Hz
FFT Data Length 1024
FFT Data Format 32 bits
Measurement

Projects

  • 1-50 THD, 1-50 level voltage and current V [n], A [n]
  • 1-50 level voltage and current distortion percentage
  • V [n%], A [n%]
  • 1-50 level watts W [n]
  • 1-50 level watts distortion percentage Watt W [n%]
  • 1-50 level voltage and current angle DEG [n]
  • Vrms, Irms, Watt, PF

 

SPEC

Model 7110 7120
Frequency Measurement Mode To achieved stable base frequency measurement (variation less than 1%) by voltage or current (non-inverter)
Frequency Range DC, 15Hz~10KHz DC, 15Hz~100KHz
Data Length Dual 4096×16 RAM for voltage & current
ADC Resolution 16 bits
Sampling Rate AC 50Hz/60Hz basic sampling rate 100 KSPS /120 KSPS
Arithmetic Precision Watt/VRMS/IRMS/MEAN/PF/Deg/Line filter 32bits
Frequency Filter 500Hz cut off, digital chip filter based on 25MHz
Signal Filter 500Hz-3db digital filter based on Butterworth 50Hz-0.03% reading,

60Hz-0.05% reading

Frequency

Acquisition Mode

Voltage / current 100MHz baseband digital dynamic meter chip
Phase Lead Detection Subject to the current, analog/digital hybrid detecting (error less than 5 degrees)

 

RMS/MEAN Mode Voltage & Current Accuracy (23℃ ±5℃ )
>=15 Hz, f  45Hz   ±(0.1% of reading + 0.4% of range)
>45 Hz,  66 Hz   ±(0.1% of reading + 0.1 % of range)
>66 Hz,  1 kHz   ±(0.1% of reading + 0.2 % of range)
>1 kHz,  10 kHz   ±(0.07*f % of reading + 0.3% of range)
>10 kHz, 100 kHz   ±(0.5% of reading + 0.5% of range) ±[{0.04×(f–10)}% of reading]
Funit is 1KHz
When the L-FILTER sets as ON: 45Hz~66Hz frequency range allowable error-0.03 %~-0.05 of reading
When the AC is measured, if the fundamental frequency exceeds 200Hz, the F-Filter is required to be turned off in order to measure the most
accurate value**When the frequency range is more than 10KHz, the 7120 starts to support

 

DC Mode Voltage & Current Accuracy (23℃ ±5℃ )
10V~600V   ±0.2% reading ± 0.2% of range
0.01A ~20A   ±{(0.2)% of reading + 0.2 % of range} ±offset
To add up the OFFSET errors of various files during measuring the DC current

 

Power (W) Accuracy (23℃ ±5℃ )
 AC power ranges (Auto or Manual)(40 ranges) range up to 16KW
Maximum Power (W) value is determined by the highest range of voltage profile
  DC ±0.2% reading ± 0.5% of range

  • 15 Hz≦f
  • 66 Hz<f≦1 kHz ±(0.2% of reading + 0.2 % of range)
  • 1 kHz<f≦10 kHz ±(0.4% of reading + 0.3 % of range)± [{0.06×(f)}% of reading]
  • 10 kHz<f≦100 kHz ±(0.5 % of reading + 0.5 % of range)±[{0.09×(f–10)}% of reading]
Incidental Allowable Error Conditions
  Signal Filter Error (AC)
  • Frequency between 45-66Hz: Add 0.3% of reading.
  • Frequency between45-66Hz: Add 1% of reading beyond
  CF9 Error (DC)      Add range tolerance * 3
Accuracy Effect of the Phase Error of the Power
 

When the power factor PF is 0, the error range of Watt is
Situation 1: for 45Hz < f, Add±1.0% of VA
Situation 2: for 45Hz > f or f > 66Hz
Add ±{(3.5 + 0.5×f )% of VA} for up to 100kHz as reference data
The unit for frequency f is kHz.
When the power factor is 0 < PF≦error range
When 0 < PF  1 (θ: phase angle of the voltage and current)
for 45Hz  f  66Hz. Add ±power reading *{tan(θ)*(0.5)}%
for f < 45Hz, f > 66Hz. Add ±power reading *{ tanθ*(0.5×f+0.2) }%

 

 Error within 12 months   Add ±(0.5% of reading)

SYSTEM

Model Support Harmonics

7110-10k-HARM

Support Harmonics

7120-100k-HARM

Don’t Support Harmonics

7110-10k

Don’t Support Harmonics

7120-100k

F71201 TEST BOX
Built-in stroage 6 Sets
Power Supply Voltage 100 ~ 240Vac
Frequency 50/60Hz
Power consumption 300VA
Environment Temperature 23℃±5℃
Humidity 20%-80%RH
Display Seven-segment display
Dimension (W*H*D) 227x101x300 mm
Weight 1.85 Kg
Interface RS-232 (7110)、RS232 + GPIB (7120)

Standard Accessories

  Power Cord
  Test Box  (F7120)
  TL218 Alligator Clips
  TL208 2mm Test Probe
  RS-232 Cable

Optional Accessories

  GPIB Cable

Enjoy:

Send Enquiry For:

Single-Phase Power Meter 7120

Israel's Leading Businesses Choose DCT

Israel's Leading Businesses Choose DCT

DCT’s Skilled Management Team has more than twenty-five years of experience and expertise in the local business environment, coupled with a highly motivated group of employees, positions us as the preferred supplier among the major customers in the industry.

DCT Competitive Edge is the prompt response to our customer needs, the online and on-site direct technical support, professional consulting for the best cost/performance solution, on-time delivery, long-term maintenance, and support.

We can get back to you!

Need a Rugged Device?

Fill in the form!

A variety of tablets are available for all use cases.
- only solutions - No obligations -

Our experts can help you find just about anything.

What Were You Looking For? Let us help.