DCT | Test and Measurement

Welcome to our new site! Feel free to report any issues, contact us at [email protected]

LCR Meter/Impedance Analyze 6632-50

LCR Meter/Impedance Analyze 6632-50

  • The LCR Meter/Impedance Analyzer 6632-50 offers a wide frequency range of 10Hz to 50MHz, making it ideal for precise impedance measurement of electronic components and materials.
  • Designed for high-accuracy testing, it provides a basic accuracy of up to ±0.08% (typical ±0.05%) and an ultra-fast measurement speed of <3ms, ensuring reliable and efficient results.
  • It supports Meter mode, List mode, and Sweep mode, allowing users to view measurement data in both numeric and graphical formats for enhanced analysis.
  • Featuring built-in DC Bias voltage (±12V), as well as measurement capabilities for permeability (μr) and dielectric constant (εr), it is equipped for advanced material testing.
  • With multiple connectivity options, including LAN, USB, GPIB, and RS-232, it seamlessly integrates with automation systems and PLC interfaces, making it ideal for industrial and laboratory applications.
Send Enquiry

The precision impedance analyzer 6632 has seven frequency options(10Hz to 1/3/5/10/20/30/50MHz).

Option 6632S

Evaluation impedance characteristics of RFID / NFC /  automotive wireless of antennas

Option 6632S

Equivalent Circuit Analysis (Option)

It has seven different models, combine with different types of parameters ( R, L, C) help customers model the impedance versus frequency characteristics and self-resonant frequency (SRF).

The induction coil for wireless charging in a mobile phone. Due to the manufacturing process, the wiring density layout from the induction coil will affect the original capacitance. The size of the parallel equivalent capacitance in the coil is the key to determine whether the product can be successful in high frequency application. It can affect the receiving function/wireless charging of an antenna. With this element analysis, we can accurately determine the RLC value to ensure the quality of the induction coil.

Option 6632S

Model E is suitable for measuring and analyzing the resonators, piezoelectric element or transducer. The two-resonance frequency characteristic diagram presented above is suited for Model E.

List Mode

50 groups of list mode setting (Each group contains up to 15 steps).

Four Parameters Displayed Simultaneously
7.0”TFT, 800×480 color screen, and four parameters can displayed simultaneously.

Measure Inductor (DCR)

Inductor coil turns and winding materials will affect DCR value. The key parameters for inductor are Ls / Lp / Q / SRF / DCR.

Evaluation of DC bias voltage characteristics with semiconductor wafer or ceramic multilayer capacitors.

Magnetic Material Test Fixture (FX-0000C8)

Using the magnetic material test fixture for measuring of permeability of various toroidal cores or ferrite cores and electromagnetic shielding coating materials, 6632 built-in formula to directly calculate the permeability coefficient value μr

Dielectric Material Test Fixture (FX-0000C7)

Liquid Dielectric Material Test Fixture (FX-000C20)

Using the dielectric material test fixture for measuring PCB board or ceramic board. 6632 built-in formula to directly calculate the material dielectric value εr ‘, εr “.Using the liquid dielectric material test fixture for measuring the characteristics of electrochemical materials.

Testing PC board  inductance coil.

MICROTEST LCR/Impedance Analyzer measures the electrical properties of passive components (inductors, capacitors, resistors), including inductance, capacitance, resistance, quality factor, dissipation factor, and impedance.

6632/6632S Impedance Analyzers operate from 10Hz to 50MHz and offer features like sweep analysis, multi-step listings, and Meter mode measurements. They come with built-in measurements of dielectric constant (εr) and magnetic permeability (μr), eliminating manual calculations or extra software. 6632S model supports seven different equivalent circuit models for a faster and more precise understanding of parasitic components’ impact on impedance.

For LCR testing, there are high-frequency 6630 series (1M/3M/5M/10M/20M/30M/50MHz) and basic 6360 series (20k/100k/500k/1MHz) options.

6630 series is ideal for automated production line testing, especially for high-speed production, while the 6360 series is suitable for general quality control and incoming material inspection (IQC).

An LCR Meter/Impedance Analyzer can be equipped with a DC Bias Current Source to analyze the magnetic saturation changes in inductors caused by current during operation. The DC bias current source test system provides the 6632/6632S+ and 6350+ series, analyzing and verifying the magnetic saturation current (Isat) and temperature rise current (Irms) of the inductor.

SPEC

Model 6632
Frequency Range 10Hz-50MHz
Frequency Setting Continuity
Frequency Resolution 100mHz, 6-bit Frequency Input
Frequency Output Accuracy ±0.01%
Basic Accuracy ±0.08% (typical ±0.05%)
AC Drive Level Test Signal Voltage Level                  10mV  2Vrms(100Ω)

                 10mV – 1Vrms(25Ω)

Voltage Minimum Resolution 1mV
Accuracy          ALC ON:6% * Voltage ±2mV

         ALC OFF:10% * Voltage ±2mV

Test Signal Current Level 200µA – 20mArms
Current Minimum Resolution 10µA
Accuracy          ALC ON:6% * Current ± 20µA

         ALC OFF:10% * Current ± 20µA

DC Drive Level 1V (fixed)
Output Impedance 25Ω/100Ω (switchable)
DC Bias Voltage Built-in ±12V

(100Hz-50MHz)

External Voltage Bias

(±12V/±40V/±600V/±2000V)

DC Bias Current Option DC Bias Current Source

(20A/60A/120A/320A)

External Voltage Bias

(100mA)

Measurement Mode Meter mode, list mode, sweep mode, and optional equivalent circuit analysis function (S model)
Measurement Parameters |Z|、|Y|、θ、X、R、G、B、L、D、Q、DCR、C、 ESR、εr 、μr
Test Time (Fastest) < 3mS

Measurement Parameters

Parameters Range
|Z| 0.000 mΩ to 9999.99 MΩ
R, X ± 0.000 mΩ to 9999.99 MΩ
|Y| 0.00000 μS to 999.999 kS
G, B ± 0.00000 μS to 999.999 kS
θRAD ± 0.00000 to 3.14159
θDEG ± 0.000° to 180.000°
Cs, Cp ± 0.00000 pF to 9999.99 F
Ls, Lp ± 0.00 nH to 9999.99 kH
D 0.00000 to 9999.99
Q 0.00 to 9999.99
Δ ± 0.00% to 9999.99%
Rdc 0.00 mΩ to 99.9999 MΩ
εr’ εr” 0 to 100000
μr’ μr” 0 to 100000

System

  Measurement Circuit Series/Parallel
  Correction Open Circuit/Short Circuit/Load correction
Cable Compensation 0 / 0.5 / 1 /2 (m)
  BIN ABS、ΔABS、Δ%、OFF
  Comparator 9
  List Mode 50 groups of Multi-steps setting (Each group contains up to 15 steps)
Bulit-in Storge 100 sets LCR setting documents, 50 groups of list mode setting
USB Host Storge LCR setting documents, list mode setting document, BMP graphics, Sweep screen and test result data
  Trigger Test Auto, manual, RS-232, GPIB, Handler
  Power Supply Voltage:90-264Vac
Frequency:47-63Hz
  Power consumption 30VA
  Environment Temperature:10℃-40℃
Humidity:20-90%RH
  Dimension 336x147x340 mm (W*H*D)
  Weight 3.95 Kg
  Interface RS-232、Handler、LAN、USB Host、USB Device
Display Color Screen, 7″ TFT (800*480)

Enjoy:

Send Enquiry For:

LCR Meter/Impedance Analyze 6632-50

Israel's Leading Businesses Choose DCT

Israel's Leading Businesses Choose DCT

DCT’s Skilled Management Team has more than twenty-five years of experience and expertise in the local business environment, coupled with a highly motivated group of employees, positions us as the preferred supplier among the major customers in the industry.

DCT Competitive Edge is the prompt response to our customer needs, the online and on-site direct technical support, professional consulting for the best cost/performance solution, on-time delivery, long-term maintenance, and support.

We can get back to you!

Need a Rugged Device?

Fill in the form!

A variety of tablets are available for all use cases.
- only solutions - No obligations -

Our experts can help you find just about anything.

What Were You Looking For? Let us help.