DCT | Test and Measurement

Welcome to our new site! Feel free to report any issues, contact us at [email protected]

LCR Meter/Impedance Analyzer 6632-1S

LCR Meter/Impedance Analyzer 6632-1S

  • The LCR Meter/Impedance Analyzer 6632-1S offers a 10Hz–1MHz frequency range with high accuracy up to ±0.08% (typical ±0.05%) for precise impedance measurement.
  • Features Equivalent Circuit Analysis to evaluate parasitic component effects on impedance.
  • Supports Meter mode, List mode, and Sweep mode with numeric and graphical data display.
  • Equipped with Automatic Level Control (ALC), switchable 25Ω/100Ω output impedance, and built-in DC Bias voltage (±12V).
  • Provides LAN, USB, GPIB, and RS-232 connectivity, ensuring seamless integration with automation systems.
Send Enquiry

MICROTEST LCR/Impedance Analyzer measures the electrical properties of passive components (inductors, capacitors, resistors), including inductance, capacitance, resistance, quality factor, dissipation factor, and impedance.

6632/6632S Impedance Analyzers operate from 10Hz to 50MHz and offer features like sweep analysis, multi-step listings, and Meter mode measurements. They come with built-in measurements of dielectric constant (εr) and magnetic permeability (μr), eliminating manual calculations or extra software. 6632S model supports seven different equivalent circuit models for a faster and more precise understanding of parasitic components’ impact on impedance.

For LCR testing, there are high-frequency 6630 series (1M/3M/5M/10M/20M/30M/50MHz) and basic 6360 series (20k/100k/500k/1MHz) options.

6630 series is ideal for automated production line testing, especially for high-speed production, while the 6360 series is suitable for general quality control and incoming material inspection (IQC).

An LCR Meter/Impedance Analyzer can be equipped with a DC Bias Current Source to analyze the magnetic saturation changes in inductors caused by current during operation. The DC bias current source test system provides the 6632/6632S+ and 6350+ series, analyzing and verifying the magnetic saturation current (Isat) and temperature rise current (Irms) of the inductor.

SPEC

Model 6632
Frequency Range 10Hz-50MHz
Frequency Setting Continuity
Frequency Resolution 100mHz, 6-bit Frequency Input
Frequency Output Accuracy ±0.01%
Basic Accuracy ±0.08% (typical ±0.05%)
AC Drive Level Test Signal Voltage Level                  10mV  2Vrms(100Ω)

                 10mV – 1Vrms(25Ω)

Voltage Minimum Resolution 1mV
Accuracy          ALC ON:6% * Voltage ±2mV

         ALC OFF:10% * Voltage ±2mV

Test Signal Current Level 200µA – 20mArms
Current Minimum Resolution 10µA
Accuracy          ALC ON:6% * Current ± 20µA

         ALC OFF:10% * Current ± 20µA

DC Drive Level 1V (fixed)
Output Impedance 25Ω/100Ω (switchable)
DC Bias Voltage Built-in ±12V

(100Hz-50MHz)

External Voltage Bias

(±12V/±40V/±600V/±2000V)

DC Bias Current Option DC Bias Current Source

(20A/60A/120A/320A)

External Voltage Bias

(100mA)

Measurement Mode Meter mode, list mode, sweep mode, and optional equivalent circuit analysis function (S model)
Measurement Parameters |Z|、|Y|、θ、X、R、G、B、L、D、Q、DCR、C、 ESR、εr 、μr
Test Time (Fastest) < 3mS

Measurement Parameters

Parameters Range
|Z| 0.000 mΩ to 9999.99 MΩ
R, X ± 0.000 mΩ to 9999.99 MΩ
|Y| 0.00000 μS to 999.999 kS
G, B ± 0.00000 μS to 999.999 kS
θRAD ± 0.00000 to 3.14159
θDEG ± 0.000° to 180.000°
Cs, Cp ± 0.00000 pF to 9999.99 F
Ls, Lp ± 0.00 nH to 9999.99 kH
D 0.00000 to 9999.99
Q 0.00 to 9999.99
Δ ± 0.00% to 9999.99%
Rdc 0.00 mΩ to 99.9999 MΩ
εr’ εr” 0 to 100000
μr’ μr” 0 to 100000

System

  Measurement Circuit Series/Parallel
  Correction Open Circuit/Short Circuit/Load correction
Cable Compensation 0 / 0.5 / 1 /2 (m)
  BIN ABS、ΔABS、Δ%、OFF
  Comparator 9
  List Mode 50 groups of Multi-steps setting (Each group contains up to 15 steps)
Bulit-in Storge 100 sets LCR setting documents, 50 groups of list mode setting
USB Host Storge LCR setting documents, list mode setting document, BMP graphics, Sweep screen and test result data
  Trigger Test Auto, manual, RS-232, GPIB, Handler
  Power Supply Voltage:90-264Vac
Frequency:47-63Hz
  Power consumption 30VA
  Environment Temperature:10℃-40℃
Humidity:20-90%RH
  Dimension 336x147x340 mm (W*H*D)
  Weight 3.95 Kg
  Interface RS-232、Handler、LAN、USB Host、USB Device
Display Color Screen, 7″ TFT (800*480)

Enjoy:

Send Enquiry For:

LCR Meter/Impedance Analyzer 6632-1S

Israel's Leading Businesses Choose DCT

Israel's Leading Businesses Choose DCT

DCT’s Skilled Management Team has more than twenty-five years of experience and expertise in the local business environment, coupled with a highly motivated group of employees, positions us as the preferred supplier among the major customers in the industry.

DCT Competitive Edge is the prompt response to our customer needs, the online and on-site direct technical support, professional consulting for the best cost/performance solution, on-time delivery, long-term maintenance, and support.

We can get back to you!

Need a Rugged Device?

Fill in the form!

A variety of tablets are available for all use cases.
- only solutions - No obligations -

Our experts can help you find just about anything.

What Were You Looking For? Let us help.