DC Bias Current Source 6225 (20A)

DC Bias Current Source 6225 (20A)

  • High Output Capability Provides a DC bias current of up to 20A per unit, designed for precise inductor testing.
  • Frequency Range Supports a frequency range of 100Hz to 3MHz with the 6632 Impedance Analyzer.
  • System Integration Works seamlessly with the 6632 Impedance Analyzer for magnetic saturation and temperature rise current analysis.
  • Compact Design Efficient and durable with power consumption of 320W max, weighs 15 kg, and operates with an input voltage of 88-264V AC.
  • Versatile Use Ideal for applications in testing inductors and other components requiring stable DC bias currents.
Send Enquiry

Features

  • Up to 30MHz
  • Each individual unit can output DC Bias Current 20A (Max.20A)
  • Control by the LCR Meter or Impedance Analyzer

Application
How DC Bias current helps inductor testing?

Ferromagnetic materials (like iron) are composed of microscopic regions called magnetic domains. The stronger the external magnetic field H, the more the domains align, yielding a higher magnetic flux density B. Eventually, The magnetization remains nearly constant, and is said to have saturated. The domain structure at saturation depends on the temperature.

What is magnetic saturation?

In electronic circuits, transformers and inductors with ferromagnetic cores operate nonlinearly when the current through them is large enough to drive their core materials into saturation. This means that their inductance and other properties vary with changes in drive current. In linear circuits this is usually considered an unwanted departure from ideal behavior.

 

Magnetic saturation current is called Isat, and the temperature rise current is called I rms. When the transformer and the inductor pass a large current in the actual circuit operation, the magnetic field of the magnetic core will produce magnetic saturation, which will cause the inductance characteristic to decline. Therefore, the R&D engineer will set the current value of the inductance reduction allowable range.

Option 6632+6243 DC Bias Curretnt Test System

Supports magnetic saturation current analysis measurement function.

Isat (Magnetic saturation current curve)

Irms (Rated current curve)

Using a DC Bias current source to apply a 200A bias current to the inductor, the inductance decreased from 2.06983uH to 1.02845uH.

Equivalent Circuit Analysis (Option)

It has seven different models, combine with different types of parameters ( R, L, C) help customers model the impedance versus frequency characteristics and self-resonant frequency (SRF).

Magnetic Material Test Fixture (FX-0000C8)

Using the magnetic material test fixture for measuring of permeability of various toroidal cores or ferrite cores and electromagnetic shielding coating materials, 6632 built-in formula to directly calculate the permeability coefficient value μr.

List Mode

50 groups of list mode setting (Each group contains up to 15 steps).

 

 

DC Bias Source Test System provides precise verification of magnetic components’ magnetic saturation current (Isat) and temperature rise current (Irms). It is equipped with a DC bias current source integrated with an LCR meter/Impedance Analyzer and can be configured as a desktop unit or integrated into a testing cabinet. Operation settings and test results are displayed on the LCR meter/Impedance Analyzer and can also be accessed through PC connection software.

The DC bias current output ranges up to a maximum of 640A/120A/60A/20A, with frequency responses of 100Hz-30MHz/10MHz/3MHz.

For research and development (R&D) or scientific research institutions, there is the option of the 6632+ / 6632S+ series, which includes a current curve sweep analysis feature.

The 6225 DC Bias Current Source is designed for performing magnetic saturation current (Isat) and temperature rise current analysis (Irms) on inductors. To conduct such analysis, it is necessary to purchase the system along with the 6632 Impedance Analyzer, which has a frequency response range of 100Hz-30MHz and a maximum output current of 20A.

Specifications

DC Bias Current Source
Model 6225
DC Bias Current Max. 20A
units of the DC Bias 1
Power consumption 320W Max.
Output Current (unit) 20A
Option LCR Meter/Impedance Analyzer Frequency Response
6632 100Hz-3MHz
DC Bias Current Source 6225
 Accuracy (6632) 0.000A-1.000A 1%+5mA
1.001A-5.000A 2%
5.001A-20.000A 3%
DCR Test
Constant power output
Current switch /

System

   Power Supply Voltage:88-264Vac
Frequency:47-63Hz
  Environment Temperature:10℃-40℃
Humidity:20-90%RH
Dimension 356x147x497 mm (W*H*D)/6225
  Weight 15 Kg (6225)
Display
Interface RS-232、Handler

Accessories

Standard Accessories

  Power Cord
  DIP Test Fixture-DC Bias Current  (F6210)

 

Optional Accessories

  PC Link Software
  SMD Test Fixture-DC Bias Current  (F6220)
  BNC+BNC cable

Enjoy:

Send Enquiry For:

DC Bias Current Source 6225 (20A)

Israel's Leading Businesses Choose DCT

Israel's Leading Businesses Choose DCT

DCT’s Skilled Management Team has more than twenty-five years of experience and expertise in the local business environment, coupled with a highly motivated group of employees, positions us as the preferred supplier among the major customers in the industry.

DCT Competitive Edge is the prompt response to our customer needs, the online and on-site direct technical support, professional consulting for the best cost/performance solution, on-time delivery, long-term maintenance, and support.

We can get back to you!

Need a Rugged Device?

Fill in the form!

A variety of tablets are available for all use cases.
- only solutions - No obligations -

Our experts can help you find just about anything.

What Were You Looking For? Let us help.